Related Experiment Video
Updated: Feb 6, 2026

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Does the Robotic Arm and Preoperative CT Planning Help with 3D Intraoperative Total Knee Arthroplasty Planning?
Robert C Marchand1, Nipun Sodhi2, Manoshi Bhowmik-Stoker3
1Department of Orthopaedic Surgery, Ortho Rhode Island, Wakefield, Rhode Island.
Abstract:
Although several studies highlight the advantages of robotic arm-assisted total knee arthroplasty (RA-TKA), few investigate its intraoperative outcome. Therefore, the purpose of this study was to analyze the RA-TKA's ability to assist with intraoperative correction of: (1) flexion and (2) extension gaps, as well as its ability to (3) accurately predict implant sizes. Additionally, in this RA-TKA cohort, length of stay, complications, and readmissions were assessed. A total of 335 patients who underwent RA-TKA were included. The robotic software virtually measured the intraoperative prebone cut extension and flexion gaps. Differences in medial versus lateral prebone cut extension and flexion gaps were calculated. A total of 155 patients (46%) had an extension gap difference of between -2 and 2 mm (mean, -0.3 mm), while 119 patients (36%) had a flexion gap difference of between -2 and 2 mm (mean, -0.6 mm). Postbone cut differences in medial versus lateral flexion and extension gaps were measured. Balanced knees were considered to have a medial and lateral flexion gap difference within 2 mm. The robot-predicted implant size was also compared with the final implant size. Additionally, lengths of stay, complications, and readmissions were assessed. All patients achieved a postbone cut extension gap difference between -1 and 1 mm (mean, -0.1 mm). A total of 332 patients (99%) achieved a postbone cut flexion gap difference of between -2 and 2 mm (mean, 0 mm). For 98% of prostheses, the robotic software predicted within 1 implant size the actual tibial or femoral implant size used.The mean length of stay was found to be 2 days. No patients suffered from superficial skin infection, pin site infections or fractures, soft tissue damage, and no robotic cases were converted to manual TKA due to intraoperative complications. A total of 8 patients (2.2%) were readmitted; however, none were directly related to robotic use. The robotic software and use of a preoperative computed tomography (CT) substantially helped with intraoperative planning and accurate prediction of implant sizes. Therefore, based on the results of this study, the RA-TKA device does, in fact, provide considerable intraoperative assistance.
Related Concept Videos
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Planning Nursing Care I
Planning Nursing Care II
Role of Communication in the Nursing Process II: Planning and Implementation
Nursing Process for Patient and Caregiver Teaching II: Planning and Implementation
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...

