Related Experiment Video
Updated: Feb 6, 2026

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Evaluation of Health or Pathology of Bilateral Maxillary Sinuses in Patients Referred for Cone Beam Computed
Abstract:
The aim of this study was to evaluate the health or pathology of bilateral maxillary sinuses using cone beam computed tomography (CBCT) with a low-dose protocol, and to analyze potential influencing factors. The study included only CBCT scans with complete visualization of bilateral maxillary sinuses. The scans were taken using a medium to large field of view and a low-dose protocol, as indicated by the manufacturer. CBCT images were analyzed with regard to the morphology of the sinus membrane and surrounding bone twice by one observer. Influencing factors such as age, sex, or status of the remaining dentition in the posterior maxilla, including periodontal and endodontic parameters, were evaluated. The study included 134 CBCT scans (268 maxillary sinuses). Using a low-dose protocol, intraobserver reliability of the measurements was almost perfect (kappa value range 0.875 to 1). More than half the sinuses evaluated (63.1%) did not show visible morphologic changes. The most frequently identified pathologic appearance was a flat, shallow thickening of the sinus membrane of > 2 mm (47 positive findings [17.5%]). Only 15 (5.6%) sinuses were associated with teeth with endodontic treatment and/or pathology, and 10 (3.7%) with teeth exhibiting periodontal pathology. CBCT scans with a low-dose protocol can be recommended as a feasible adjunctive tool to evaluate health or pathology of the maxillary sinuses prior to surgical interventions such as sinus floor augmentation. Of all morphologic changes seen, only a small portion of the cases were considered to need further medical diagnosis/treatment.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients
Imaging Studies III: Computed Tomography
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Inertial Frames of Reference