Related Experiment Video
Updated: Feb 6, 2026

A Patient-Derived Xenograft Model for Venous Malformation
Published on: June 15, 2020
Strong correlation of lumefantrine concentrations in capillary and venous plasma from malaria patients
Liusheng Huang1, Norah Mwebaza2,3, Richard Kajubi3
1Drug Research Unit, Department of Clinical Pharmacy, University of California, San Francisco, CA, United States of America.
Background:
Lumefantrine is a long-acting antimalarial drug with an elimination half-life of over 3 days and protein binding of 99 percent. Correlation of lumefantrine concentrations from capillary plasma via fingerprick (Cc) versus venous plasma (Cv) remains to be defined.
Methods:
Venous and capillary plasma samples were collected simultaneously from children, pregnant women, and non-pregnant adults at 2, 24, 120hr post last dose of a standard 3-day artemether-lumefantrine regimen they received for uncomplicated malaria. Some of the enrolled children and pregnant women were also HIV-infected. Samples were analyzed via liquid chromatography tandem mass spectrometry. Linear regression analysis was performed using the program Stata® SE12.1.
Results:
In children, the linear regression equations for Cc vs Cv at 2, 24, and 120hr (day 7) post dose are [Cc] = 1.05*[Cv]+95.0 (n = 142, R2 = 0.977), [Cc] = 0.995*[Cv]+56.7 (n = 147, R2 = 0.990) and [Cc] = 0.958*[Cv]+18.6 (n = 139, R2 = 0.994), respectively. For pregnant women, the equations are [Cc] = 1.04*[Cv]+68.1 (n = 43, R2 = 0.990), [Cc] = 0.997*[Cv]+37.3 (n = 43, R2 = 0.993) and [Cc] = 0.941*[Cv]+11.1 (n = 41, R2 = 0.941), respectively. For non-pregnant adults, the equations are [Cc] = 1.05*[Cv]-117 (n = 32, R2 = 0.958), [Cc] = 0.962*[Cv]+9.21 (n = 32, R2 = 0.964) and [Cc] = 1.04*[Cv]-40.1 (n = 32, R2 = 0.988), respectively. In summary, a linear relationship with a slope of ~1 was found for capillary and venous lumefantrine levels in children, pregnant women and non-pregnant adults at 2hr, 24hr and 120hr post last dose, representing absorption, distribution, and elimination phases.
Conclusions:
Capillary and venous plasma concentration of lumefantrine can be used interchangeably at 1:1 ratio. Capillary sampling method via finger prick is a suitable alternative for sample collection in clinical studies.
Related Concept Videos
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Correlations
Strong Acid and Base Solutions
Titration of a Strong Acid with a Strong Base
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...