Secondary Neutron Dose From a Dynamic Collimation System During Intracranial Pencil Beam Scanning Proton Therapy: A
Blake R Smith1, Daniel E Hyer2, Patrick M Hill3
1Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin.
Purpose:
Patients receiving pencil beam scanning (PBS) proton therapy with the addition of a dynamic collimation system (DCS) are potentially subject to an additional neutron dose from interactions between the incident proton beam and the trimmer blades. This study investigates the secondary neutron dose rates for both single-field uniform dose (SFUD) and intensity modulated proton therapy treatments.
Methods And Materials:
Secondary neutron dose distributions were calculated for both a dynamically collimated and an uncollimated, dual-field chordoma treatment plan and compared with previously published neutron dose rates from other contemporary scanning treatment modalities. Monte Carlo N-Particle transport code was used to track all primary and secondary particles generated from nuclear reactions within the DCS during treatment through a model of the patient geometry acquired from the computed tomography planning data set. Secondary neutron ambient dose equivalent distributions were calculated throughout the patient using a meshgrid with a tally resolution equivalent to that of the treatment planning computed tomography.
Results:
The median healthy-brain neutron ambient dose equivalent for a dynamically collimated intracranial chordoma treatment plan using a DCS was found to be 0.97 mSv/Gy for the right lateral SFUD field, 1.37 mSv/Gy for the apex SFUD field, and 1.24 mSv/Gy for the composite intensity modulated proton therapy distribution from 2 fields.
Conclusions:
These results were at least 55% lower than what has been reported for uniform scanning modalities with brass apertures. However, they still reflect an increase in the excess relative risk of secondary cancer incidence compared with an uncollimated PBS treatment using only a graphite range shifter. Regardless, the secondary neutron dose expected from the DCS for these PBS proton therapy treatments appears to be on the order of, or below, what is expected for alternative collimated proton therapy techniques.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Secondary Active Transport
Leaky Scanning
Secondary Healthcare System