Related Experiment Video
Updated: Feb 6, 2026

A Microplate Assay to Assess Chemical Effects on RBL-2H3 Mast Cell Degranulation: Effects of Triclosan without Use of an Organic Solvent
Published on: November 1, 2013
A cyclodextrin polymer membrane-based passive sampler for measuring triclocarban, triclosan and methyl triclosan in
Mengbi Wei1, Xianhai Yang1, Peter Watson2
1Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, Jiangsu Province, China.
Abstract:
In recent years, extensive attention has been paid to the passive sampling technology of diffusive gradients in thin films (DGT) due to its growing application in the measurement of a widening variety of compounds. Within any DGT device, the binding phase is a key component, and seeking novel binding phases is an issue worth studying. Cyclodextrin polymer, as a green and eco-friendly material, may be a good choice for measuring organic chemicals. In this study, a novel DGT sampler with cyclodextrin polymer membrane (CDPM) as the binding phase was developed for measuring the concentrations of triclosan, triclocarban and methyl triclosan. Firstly, the type and content of cyclodextrin used in CDPM was optimized, and a series of tests showed that CDPM had good hydrophilicity, thermal stability, fast uptake rate and sufficient uptake capacity, thus CDPM was determined to be suitable for use as the binding phase of DGT sampler. Moreover, the sampling rates of this DGT sampler were not influenced by ionic strength and dissolved organic matter, making it feasible for in situ monitoring of compounds in the field. Hence, we deployed the developed DGT sampler in the Qinhuai and Jiuxiang Rivers to measure the concentrations of three compounds. We also collected water samples and processed them with the solid phase extraction (SPE) method. Results indicated that there was no significant difference between the DGT-measured and the SPE-measured concentrations for each compound, which confirmed the reliability of this DGT sampler for monitoring the concentrations of compounds in natural waters.
More Related Videos
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
Related Concept Videos
Drug Absorption Mechanism: Passive Membrane Transport
Polymers
Polymers
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
The Resting Membrane Potential