Estimating the rapid haemodynamic effects of passive leg raising in critically ill patients using bioreactance
L Galarza1, P Mercado1, J-L Teboul1
1Service de Réanimation Médicale, Hôpital de Bicêtre, Hôpitaux Universitaires Paris-Sud, Assistance Publique - Hôpitaux de Paris, Inserm UMR S_999, Université Paris-Sud, Le Kremlin-Bicêtre, France.
Background:
Rapid detection of changes in cardiac index (CI) in real time using minimally invasive monitors may be of clinical benefit. We tested whether the Starling-SV bioreactance device, which averages CI over a short 8 s period, could assess the effects of passive leg raising (PLR), a clinical test that is recommended to assess fluid responsiveness during septic shock.
Methods:
In 32 critically ill patients, we measured CI by transpulmonary thermodilution (PiCCO2, CItd), pulse contour analysis (PiCCO2, CIPulse), and the Starling-SV device (CIStarling) at baseline. CIPulse and CIStarling were measured again at the end of a PLR test. In the 13 patients with a positive PLR test, CItd, CIPulse, and CIStarling were measured before and after a 500 ml saline infusion. The primary outcome was relative changes from baseline measurements in CItd, CIPulse, and CIStarling. Secondary outcomes compared absolute values measured by each method.
Results:
Relative changes in CIPulse and CItd were significantly correlated (r=0.82; n=45; P<0.001), with an 89% concordance rate (n=45 paired measurements). Relative changes in CIStarling and CItd were also significantly correlated (r=0.59; n=45; P<0.001) with a 78% concordance rate. For absolute measures of CI (n=77 paired measurements), the bias between CIPulse and CItd was 0.01 L min-1 m-2 (limits of agreement, -0.49 and 0.51 L min-1 m-2; 15% percentage error). Bias between CIStarling and CItd was 0.03 L min-1 m-2 (limits of agreement, -1.61 and 1.67 L min-1 m-2; 48% percentage error).
Conclusions:
In critically ill patients, a non-invasive bioreactance device with a shorter averaging period assessed a passive leg raising test with reasonable accuracy.
Related Concept Videos
Muscles that Move the Leg
Anterior Compartment
The quadriceps femoris, the most visible muscle of the anterior compartment, is integral for leg extension and thigh flexion. It is formed by merging four distinct muscles — the vastus lateralis, vastus medialis, vastus intermedius, and rectus femoris. The quadriceps tendon, a shared tendon of the four quadriceps muscles, is affixed...
Pharmacodynamics in Geriatric Patients: Effects of Age
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...
Critical Values
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...