Related Experiment Video
Updated: Feb 6, 2026

Surface Enhanced Raman Spectroscopy Detection of Biomolecules Using EBL Fabricated Nanostructured Substrates
Published on: March 20, 2015
Comparative Computational and Experimental Detection of Adenosine Using Ultrasensitive Surface-Enhanced Raman
Emma M Sundin1,2, John D Ciubuc3,4, Kevin E Bennet5
1Department of Physics, University of Texas at El Paso, El Paso, TX 79968, USA. emsundin@miners.utep.edu.
Abstract:
To better understand detection and monitoring of the important neurotransmitter adenosine at physiological levels, this study combines quantum chemical density functional modeling and ultrasensitive surface-enhanced Raman spectroscopic (SERS) measurements. Combined simulation results and experimental data for an analyte concentration of about 10-11 molar indicate the presence of all known molecular forms resulting from adenosine's complex redox-reaction. Detailed analysis presented here, besides assessing potential Raman signatures of these adenosinic forms, also sheds light on the analytic redox process and voltammetric detection. Examples of adenosine Raman fingerprints for different molecular orientations with respect to the SERS substrate are the vibrational line around 920 ± 10 cm-1 for analyte physisorption through the carbinol moiety and around 1600 ± 20 cm-1 for its fully oxidized form. However, both hydroxyl/oxygen sites and NH₂/nitrogen sites contribute to molecule's interaction with the SERS environment. Our results also reveal that contributions of partially oxidized adenosine forms and of the standard form are more likely to be detected with the first recorded voltammetric oxidation peak. The fully oxidized adenosine form contributes mostly to the second peak. Thus, this comparative theoretical⁻experimental investigation of adenosine's vibrational signatures provides significant insights for advancing its detection, and for future development of opto-voltammetric biosensors.
More Related Videos
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Comparing Experimental Results: Student's t-Test
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...