Related Experiment Video
Updated: Feb 6, 2026

Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
An anatomical study of the spinous process of the seventh cervical vertebrae based on the three-dimensional computed
Lei Zhang1,2, Zidan Luo2,3, Hao Wang4
1Department of Orthopedics, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, Sichuan 646600, P.R. China.
Abstract:
Palpation of the seventh cervical vertebra (C7) is important for the diagnosis and treatment of neck and chest conditions. However, the spinous process of C7 (C7-SP) displays an anatomical deviation among individuals. The present study aimed to clarify anatomic characteristics of C7-SP by using a three-dimensional (3D) computed tomographic (CT) reconstruction technique. A total of 245 subjects meeting the selection criteria were examined. After CT scanning, the images were reconstructed in 3D. All subjects were grouped according to their deviation of C7-SP: Deviating to the right (DR group), deviating to the left (DL group) and no deviation (ND group). Three distances and three angles were recorded on C7-SP. The vertical distances between the borders of the left and right transverse processes and the tip of the SP, were termed DLTS and DRTS, respectively. The length of the SP was also determined. The angle of the SP deviation was referred to as ∠α, the angle between the SP axis and the line crossing the tips of the transverse processes was referred to as ∠β and the angle between the vertebral body axis and the SP axis was referred to as ∠γ. Among the three groups, differences in ∠α and ∠β were statistically significant (P<0.05). Furthermore, the DLTS was significantly different between the DL and ND groups (P<0.05). In addition, a significant difference in the DRTS was identified between the DR and ND groups (P<0.05). 3D CT reconstruction was reliable for studying anatomic characteristics of C7-SP. Based on this, patients may be preliminarily grouped according to the deviation of their C7-SP and the measurement of the C7-SP may guide clinical diagnoses and treatments.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
11:09Construction of a Realistic, Whole-Body, Three-Dimensional Equine Skeletal Model using Computed Tomography Data
Published on: February 25, 2021
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
General Structure of a Vertebra
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Anatomical Terminology