Validating Left Ventricular Filling Pressure Measurements in Patients with Congestive Heart Failure: CardioMEMS™
Sunit Tolia1, Zubair Khan1, Gunjan Gholkar1
1Department of Cardiology, Providence-Providence Park Hospital, Michigan State University College of Human Medicine, 16001 W. Nine Mile Road, Southfield, MI 48075, USA.
Background:
Routine ambulatory echocardiographic estimates of left ventricular (LV) filling pressures are not cost-effective and are occasionally fraught with anatomic, physiologic as well as logistical limitations. The use of implantable hemodynamic devices such as CardioMEMS Heart Failure (HF) System has been shown to reduce HF-related readmission rates by remote monitoring of LV filling pressures. Little is known about the correlation between CardioMEMS and echocardiography-derived estimates of central hemodynamics.
Methods:
We performed a prospective, single-center study enrolling seventeen participants with New York Heart Association functional class II-III HF and preimplanted CardioMEMS sensor. Simultaneous CardioMEMS readings and a limited echocardiogram were performed at individual clinic visits. Estimated left atrial pressure (LAP) by echocardiogram was calculated by the Nagueh formula. Linear regression was used as a measure of agreement. Variability between methods was evaluated by Bland-Altman analysis.
Results:
Mean age was 74 ± 9 years; 59% (10/17) were males. LV systolic dysfunction was present in 76% (13/17) of subjects. Mean PAdP was 18 ± 4 mmHg and 19 ± 5 mmHg for CardioMEMS and echocardiographic-derived estimates, respectively, with a significant correlation between both methods (r2=0.798, p ≤ 0.001).
Conclusions:
Our study illustrates a direct linear correlation between PAdP measured by CardioMEMS and simultaneous measurement of LV filling pressures derived by echocardiography.
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Vapor Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.