Reduction of spike generation frequency by cooling in brain slices from rats and from patients with epilepsy
Sadahiro Nomura1,2, Hiroyuki Kida3, Yuya Hirayama1
1Department of Neurosurgery, Yamaguchi University Graduate School of Medicine, Yamaguchi, Japan.
Abstract:
This study aimed to understand the mechanism by which brain cooling terminates epileptic discharge. Cortical slices were prepared from rat brains (n = 19) and samples from patients with intractable epilepsy that had undergone temporal lobectomy (n = 7). We performed whole cell current clamp recordings at approximately physiological brain temperature (35℃) and at cooler temperatures (25℃ and 15℃). The firing threshold in human neurons was lower at 25℃ (-32.6 mV) than at 35℃ (-27.0 mV). The resting potential and spike frequency were similar at 25℃ and 35℃. Cooling from 25℃ to 15℃ did not change the firing threshold, but the resting potential increased from -65.5 to -54.0 mV and the waveform broadened from 1.85 to 6.55 ms, due to delayed repolarization. These changes enhanced the initial spike appearance and reduced spike frequency; moreover, spike frequency was insensitive to increased levels of current injections. Similar results were obtained in rat brain studies. We concluded that the reduction in spike frequency at 15℃, due to delayed repolarization, might be a key mechanism by which brain cooling terminates epileptic discharge. On the other hand, spike frequency was not influenced by the reduced firing threshold or the elevated resting potential caused by cooling.
More Related Videos
09:32Network Analysis of Foramen Ovale Electrode Recordings in Drug-resistant Temporal Lobe Epilepsy Patients
Published on: December 18, 2016
08:23A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy
Published on: November 13, 2016
Related Concept Videos
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
Oxidation-Reduction Reactions
Frequency-dependent Selection
Epilepsy and Seizures: Overview
Various factors can trigger epilepsy, including genetic factors, brain damage, metabolic causes, and unknown etiology. Diagnosis of epilepsy involves electroencephalography (EEG), which...
What is a Frequency Distribution
Mean From a Frequency Distribution
When such a data set is encountered,...