A Novel Infant Chest Compression Assist Device Using a Palm Rather Than Fingers: A Randomized Crossover Trial
Abstract:
Objective: We developed a novel compression assist device (palm presser) to perform chest compressions using a palm in infant cardiopulmonary resuscitation (CPR). We hypothesized that the palm presser will increase compression depth without increasing hands-off time and will reduce rescuer fatigue compared with the two-finger technique (TFT).Methods: In this randomized crossover manikin trial, participants performed two minutes of CPR with a 30:2 compression:ventilation ratio using the palm presser and the TFT in randomized sequence on an infant manikin. CPR parameters, including compression depth and hands-off time, were collected to compare CPR quality between the palm presser and the TFT. The linear mixed-effect model was used to control the carryover effect of a crossover design in the analysis of CPR parameters. To evaluate rescuer fatigue, we compared changes in compression depth over time and calculated the odds of sufficiently deep compressions over time between the two groups.Results: The palm presser resulted in greater mean compression depth (41.5 ± 1.6 mm vs. 36.8 ± 5.5 mm, p < 0.001), greater sufficiently deep compressions (80.9 ± 27.8% vs. 42.4 ± 35.4%, p < 0.001), and better correct hand position (99.9 ± 0.5% vs. 83.9 ± 25.3%, p = 0.013) than the TFT. Total compressions, compression rate, total ventilations, volume of ventilations, and hands-off time were not significantly different between the two groups. The mean change in compression depth over time was greater with the TFT than with the palm presser (regression coefficient: -0.024 [95% CI -0.030 to -0.018] vs. -0.004 [95% CI -0.006 to -0.002]). The odds of a compression depth greater than 40 mm increased 2.8 times (95% CI 2.2 to 3.4) with the TFT during the first minute compared with the last minute, whereas the corresponding odds ratio when using the palm presser was not significantly different in the first and last minutes (OR: 1.2 [95% CI 0.9 to 1.5]).Conclusions: Compression with palm pressers resulted in greater compression depth without increasing hands-off time and reduced rescuer fatigue compared with compression with the TFT in simulated infant CPR with manikins.
More Related Videos
08:53Randomized, Triple-Blind, and Parallel-Controlled Trial of Transcranial Direct Current Stimulation for Cognitive Rehabilitation after Stroke
Published on: June 6, 2025
03:26Author Spotlight: Advancements and Challenges in Surgical Treatments for Postamputation Pain
Published on: March 8, 2024
Related Concept Videos
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Flail Chest-I
Flail chest is a severe and potentially life-threatening condition characterized by the fracture of three or more adjacent ribs in multiple places. It is most commonly caused by direct impacts and trauma, such as motor vehicle accidents or injuries from a steering wheel impact. It can also occur due to falls in elderly individuals with osteoporosis, or assaults involving sharp objects.
Pathophysiology
The pathophysiology of flail chest is complex, involving fractures of...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...
Clinical Trials: Overview
Trial and Error and Algorithm