Related Experiment Video
Updated: Feb 6, 2026

Reduction in Left Ventricular Wall Stress and Improvement in Function in Failing Hearts using Algisyl-LVR
Published on: April 8, 2013
Left ventricular MRI wall motion assessment by monogenic signal amplitude image computation
Narjes Benameur1, Enrico Gianluca Caiani2, Martino Alessandrini3
1University of Tunis El Manar, Higher Institute of Medical Technologies of Tunis, Laboratory of Biophysics and Medical Technology, Tunis, Tunisia.
Background:
Cardiac Magnetic Resonance Imaging (MRI) is the commonly used technique for the assessment of left ventricular (LV) function. Apart manually or semi-automatically contouring LV boundaries for quantification of By visual interpretation of cine images, assessment of regional wall motion is performed by visual interpretation of cine images, thus relying on an experience-dependent and subjective modality.
Objective:
The aim of this work is to describe a novel algorithm based on the computation of the monogenic amplitude image to be utilized in conjunction with conventional cine-MRI visualization to assess LV motion abnormalities and to validate it against gold standard expert visual interpretation.
Methods:
The proposed method uses a recent image processing tool called "monogenic signal" to decompose the MR images into features, which are relevant for motion estimation. Wall motion abnormalities are quantified locally by measuring the temporal variations of the monogenic signal amplitude. The new method was validated by two non-expert radiologists using a wall motion scoring without and with the computed image, and compared against the expert interpretation. The proposed approach was tested on a population of 40 patients, including 8 subjects with normal ventricular function and 32 pathological cases (20 with myocardial infarction, 9 with myocarditis, and 3 with dilated cardiomyopathy).
Results:
The results show that, for both radiologists, sensitivity, specificity and accuracy of cine-MRI alone were similar and around 59%, 77%, and 71%, respectively. Adding the proposed amplitude image while visualizing the cine MRI images significantly increased both sensitivity, specificity and accuracy up to 75%, 89%, and 84%, respectively.
Conclusion:
Accuracy of wall motion interpretation adding amplitude image to conventional visualization was proven feasible and superior to standard image interpretation on the considered population, in inexperienced observers. Adding the amplitude images as a diagnostic tool in clinical routine is likely to improve the detection of myocardial segments presenting a cardiac dysfunction.
More Related Videos
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Plant Cell Wall
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...