Dual-Energy Spectral Computed Tomography With Adaptive Statistical Iterative Reconstruction for Improving Image
Weibing Wang, Jinbai Huang, Ai Wang
1Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Anhui, Hefei, China.
Objective:
The aim of the study was to investigate whether spectral computed tomography (CT) plus adaptive statistical iterative reconstruction (ASIR) could improve imaging quality of computed tomography portal venography (CTPV).
Methods:
Sixty-four patients underwent CTPV, with CT number of portal vein (PV) less than 150 HU in portal phase, were divided into 2 groups A (n = 31), using standard 120-kVp protocol. group B (n = 33), using spectral CT protocol. Standard 120-kVp images were reconstructed with 40% ASIR, and monochromatic images at 60 keV were reconstructed with the following 4 ASIR percentages: 0%, 20%, 40%, and 60%. The CT number, image noise, and contrast-to-noise ratio in main PV were measured. The maximum intensity projection and volume-rendering images were used for subjective evaluation. These 2 kinds of results were statistically analyzed.
Results:
The contrast-to-noise ratio and subjective scoring of PV increased gradually from 120-kVp images to 60% weight ASIR (3.44 ± 0.95, 4.58 ± 1. 59, 5.26 ± 1.85, 6.18 ± 2.18, and 7.39 ± 2.65 and 4.35 ± 1.17, 6.21 ± 1.29, 6.48 ± 1.35, 6.85 ± 1.28, and 7.00 ± 1.19). There were statistically different for the 5 groups (P < 0.001). The CT number of the PV in the 60-kiloelectron volt spectral images had higher than the 120-kVp images (P < 0.001). The noise of 120 kVp was significantly higher than those of 60% ASIR and significantly lower than those of 0% ASIR (both P < 0.001), and there were no significant differences between 120-kVp, 20% ASIR, and 40% ASIR (P = 0.107 and 1.000, respectively). The diagnostic acceptability was highest at 40% ASIR.
Conclusions:
Forty-percent ASIR addition to the 60-kiloelectron volt monochromatic image could improve image quality of CTPV comparing with conventional 120-kVp images.
More Related Videos
07:58Computational Reconstruction of Pancreatic Islets as a Tool for Structural and Functional Analysis
Published on: March 9, 2022
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Statistical Significance
Hepatic Portal System
At its core, the hepatic portal vein is the result of a confluence of the superior and inferior mesenteric veins along with the splenic vein. Each of these veins has a unique role. The superior mesenteric vein is...
Probability in Statistics
An example of a simple event is a coin toss. The result of a coin toss is either a head or a tail. Here, head and tail are two simple events. These two simple events make up the sample space. Further, the probability of an event occurring falls within the range of 0 to 1. The probability of an...