Development and validation of a UPLC-MS/MS method for quantification of osimertinib (AZD9291) and its metabolite
Xin Zheng1, Weicong Wang2, Yanbao Zhang1
1Clinical Pharmacology Research Center, Peking Union Medical College Hospital, China.
Abstract:
Osimertinib (AZD9291) is a highly selective irreversible epidermal growth factor receptor tyrosine kinase inhibitor (EGFR TKI) designed to treat nonsmall-cell lung cancer patients with EGFR active and T790 M resistant mutations. A rapid and sensitive method for quantitative analysis by ultra-performance liquid chromatography-tandem mass spectrometry of osimertinib and its metabolite AZ5104 in human plasma was developed and validated. The samples were prepared by protein precipitation and separated on a BEH C18 column (2.1 × 50 mm, 1.7 μm) by gradient elution with 0.1% (v/v) formic acid and 10 mm ammonium acetate in water and acetonitrile as the mobile phase. Electrospray ionization in positive ion mode and multiple reaction monitoring were used to monitor the ion transitions at m/z 500.4 → 385.3 and 486.3 → 371.1. The results indicated that the method had excellent sensitivity and specificity. The validation was performed in a range from 0.5 to 100 ng/mL. Intra-day and inter-day precisions (in terms of RSD) were all <15%, and the accuracies (in terms of RE) were within ±15%. The lower limit of quantification, matrix effect, extraction recovery, stability and dilution integrity were also validated and satisfied the validation criteria. Finally, this method was successfully applied in a retrospective analysis, and the predose samples of 52 nonsmall-cell lung cancer patients who were enrolled in a novel third EGFR TKI clinical trial were analyzed for screening regardless of whether they had previously received osimertinib treatments.
Insights
A new ultra-performance liquid chromatography-tandem mass spectrometry method accurately quantifies osimertinib and its metabolite in plasma. This validated assay is crucial for monitoring non-small cell lung cancer patients treated with epidermal growth factor receptor tyrosine kinase inhibitors.
Area of Science:
- Analytical Chemistry
- Pharmacology
- Oncology
Background:
- Osimertinib is a targeted therapy for non-small cell lung cancer (NSCLC) with specific EGFR mutations.
- Accurate quantification of osimertinib and its metabolite is essential for therapeutic drug monitoring and clinical trials.
Purpose of the Study:
- To develop and validate a sensitive and rapid ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method.
- To quantify osimertinib and its major metabolite, AZ5104, in human plasma.
Main Methods:
- Protein precipitation for sample preparation.
- BEH C18 column with gradient elution using formic acid and ammonium acetate in water/acetonitrile.
- Electrospray ionization in positive mode with multiple reaction monitoring (MRM).
Main Results:
- The UPLC-MS/MS method demonstrated excellent sensitivity and specificity.
- Validation parameters including precision (<15% RSD), accuracy (±15% RE), LLOQ, matrix effect, recovery, stability, and dilution integrity met acceptance criteria.
- The method successfully analyzed plasma samples from NSCLC patients in a clinical trial.
Conclusions:
- A robust and validated UPLC-MS/MS method for osimertinib and AZ5104 quantification in human plasma was established.
- This method is suitable for retrospective analysis and screening in clinical settings, supporting the use of third-generation EGFR TKIs in NSCLC treatment.
More Related Videos
10:22Improved UPLC-UV Method for the Quantification of Vitamin C in Lettuce Varieties Lactuca sativa L. and Crop Wild Relatives Lactuca spp.
Published on: June 30, 2020
11:02Identification and Quantification of Deranged Metabolites in Critically Ill Patients Using NMR-Based Metabolomics
Published on: November 29, 2024
Related Concept Videos
Reliability and Validity
In Vitro Drug Release Testing: Overview, Development and Validation
Development of Analytical Methods
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Sustainable Development