Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Direct immersion solid-phase microextraction analysis of multi-class contaminants in edible seaweeds by gas
Li Zhang1, Emanuela Gionfriddo2, Vinicius Acquaro3
1Department of Chemistry, University of Waterloo, Waterloo, Ontario, Canada; Fourth Institute of Oceanography, State Oceanic Administration, Beihai, Guangxi, China.
Abstract:
The present work aimed at the development of a simple and accurate direct immersion-solidphase microextraction-gas-chromatography-mass spectrometry (DI-SPME-GC-MS) method for simultaneous determination of PAHs, PCBs, and pesticide residues in edible seaweeds. As the target contaminants possess a wide range of physical-chemical properties, multivariate experimental design was used for method optimization. In particular, two different methods were optimized and validated: one that allows for simultaneous determination of all targets, and an ad hoc method for determination of hydrophobic analytes, a class that often poses a challenge for extraction from food matrices. Optimum conditions suitable for simultaneous quantitation of all targeted compounds, namely buffer at pH = 7.0, 20% acetone (v/v), 10% NaCl (w/w), 0.02% NaN3, 60 min DI extraction at 55 °C, and 20 min desorption at 270 °C, afforded limits of quantitation (LOQs) in the range of 1-30 μg kg-1, a wide linear range of 5-2000 μg kg-1, the attainment of satisfactory determination coefficients (R2˃0.99) with no significant lack of fit (p > 0.05) at the 5% level, and satisfactory accuracy and precision values. By modifying the extraction conditions to favor extraction of the most hydrophobic analytes (e.g. higher amount of organic modifier and pH, and lower salt content) lower LOQs were obtained for these compounds ranging from 0.2 to 13.3 μg kg-1. The established methods were then used for screening of commercial, edible dry seaweeds, with PCBs (≤16.0 ng g-1) and PAHs (≤15.5 ng g-1) detected in some samples. This method overcomes most challenges commonly encountered in dry sample analysis applications, and represents the first report of a DI-SPME method employing the matrix-compatible fiber for simultaneous multiclass and multiresidue analysis of seaweeds.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II