Measurement of Trabecular Bone Score of the Spine by Low-Dose Imaging System (EOS®): A Feasibility Study
S Kolta1, A Etcheto2, J Fechtenbaum2
1Department of Rheumatology, Cochin Hospital, Assistance Publique-Hôpitaux de Paris, Paris, France; INSERM UMR-1153, Paris, France.
Abstract:
Purpose/Introduction: Measurement of trabecular bone score (TBS®) of the lumbar spine on dual energy X-ray absorptiometry (DXA) devices improves fracture risk prediction. We conducted a proof of concept study to assess the feasibility of TBS® measured on the low-dose imaging system EOS®.
Methods:
TBS was assessed on both DXA and EOS® in 122 patients aged ≥ 50 yr, receiving no anti-osteoporotic treatment. The TBS® was computed on full-body EOS® images, focusing on the lumbar spine region. The patients were also scanned with a DXA bone densitometer (Hologic) and the spine and hip bone mineral density (g/cm²) were computed.
Results:
TBS® measurement on EOS® was not possible in 34 patients due to technical problems. It could be measured on both DXA and EOS® in 88 patients (28 with severe low-trauma fracture and 60 without fracture). TBS-EOS values were significantly lower in fractured patients compared to nonfractured patients. TBS-EOS was associated with the presence of fractures as reported by an AUC of 0.70. Odds ratio of TBS-EOS for the presence of severe low-trauma fracture was 2.00 [1.24-3.25], p = 0.005.
Conclusions:
This proof of concept study, based on a prototype version of the TBS-EOS, demonstrated the feasibility of the measurement of TBS® on low-dose EOS® imaging devices. Results show that the TBS-EOS was lower in patients with severe low-trauma fractures compared to nonfractured patients independently from bone mineral density. Some technical issues need to be solved before its eventual use in routine clinical settings. Additional prospective studies are still needed to define the actual contribution of this new technique.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Bioavailability Study Design: Single Versus Multiple Dose Studies
Introduction to z Scores
z scores...
Introduction to z Scores
z scores...
z Scores and Area Under the Curve
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...