Computational analysis on the feasibility of transverse iliosacral screw fixation for different sacral segments
Yingchao Yin1, Ruipeng Zhang1, Shilun Li1
1Department of Orthopaedic Surgery, The Third Hospital of Hebei Medical University, Street address: No. 139 Ziqiang Road, Qiaoxi District, Shijiazhuang, 050051, Hebei Province, China.
Purpose:
To evaluate the feasibility of transverse iliosacral (TIS) screw placement in different segments of the sacrum and measure the parameters of the unilateral iliosacral (IS) screw in the case that cannot be inserted the TIS screw.
Methods:
This study used 100 pelvic continuous computed tomography images. Mimics (Materialise Interactive Medical Image Control System) was used to reconstruct the three-dimensional pelvis model. All sacrums were divided into the normal group and dysmorphic group. Any difference in osseous fixation pathway (OFP) diameter in the first two segments between both groups was investigated. In dysmorphic sacrums, the optimal inserting angle and length of the unilateral S1 screw were measured. The number of foramen in every sacrum was recorded.
Results:
Thirty-two sacrums had sacral dysmorphism. The OFP diameter for the S2 TIS screw in the dysmorphic group was larger than that in the normal group (p = 0.02). Receiver operating characteristic curve analysis indicated the cutoff values as 20.55 mm and 15.18° for the S1 front edge height and S1S2 angle, respectively. In the dysmorphic case, the unilateral S1 IS screw should be inserted with a cephalad incline angle of 36.14 ± 5.97° and a ventrally incline angle of 37.33 ± 4.64°. S3 TIS screw placement rate was 53.1% in the dysmorphic group.
Conclusions:
The most common cause of sacral dysmorphism is the fusion of the L5 to the true S1. In dysmorphic sacrums, the unilateral IS screw should be placed obliquely in the S1 segment, and the S2 segment usually has a sufficient OFP for the TIS screw. Using S3 TIS screw and two TIS screws in the first segment technique is not recommended because of a high risk.
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Speed of a Transverse Wave
One of the key properties of any wave is the wave speed. Light...
Deformations in a Transverse Cross Section
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...