Related Experiment Video
Updated: Feb 6, 2026

High-resolution Time-lapse Imaging and Automated Analysis of Microtubule Dynamics in Living Human Umbilical Vein Endothelial Cells
Published on: August 13, 2016
Investigating the time-lapsed effects of rigid cervical collars on the dimensions of the internal jugular vein
Jenna Kroeker1, Jay Keith1, Hailey Carruthers1
1Keith B. Taylor Global Scholars Program at Northumbria University, St. George's International School of Medicine, Newcastle-upon-Tyne, NE1 8ST, UK.
Abstract:
Protocol advocates the use of rigid cervical collars (RCCs) in head trauma patients as they are at risk of concomitant cervical spine injury. Literature has shown RCCs to be a potential cause of venous outflow obstruction, changing internal jugular vein (IJV) cross-sectional area (CSA), and raising intracranial pressure (ICP). This study aims to investigate the effects of applying a RCC, for a period of four hours, on the dimensions of the IJV, in healthy participants. Seventeen participants (nine male, eight female) took part in this study. Circumference and CSAs of the IJV were measured bilaterally by a single observer using a GE LOGIQ e ultrasound system. Measurements were taken pre-RCC application, immediately after, every hour over four hours, and five minutes postcollar removal. The CSA of the IJV was 8.3 ±6.0 mm2 pre-RCC application. The CSA of the IJV doubled (18.92 ±10.55 mm2 ) after four hours and decreased back to 9.36 ±6.8 mm2 five minutes postcollar removal. The circumference of the IJV was 17.29 ±6.03 mm pre-RCC application, increasing to 20.34 ±5.59 mm by the end of the fourth hour and returning to 16.14 ±5.16 mm five minutes postcollar removal. Related-samples Friedman's ANOVA test showed statistically significant differences for both left and right CSAs and circumferences of the IJV measured across the four hours (P-value<0.05). Ultrasound assessment of CSA of the IJV may correlate with changes in ICP. Further studies may provide insight into the effects of collar design, and guide future trauma protocol to minimize intracranial pressure fluctuations. Clin. Anat. 32:196-200, 2019. © 2018 Wiley Periodicals, Inc.
More Related Videos
08:27Adult Mouse Venous Hypertension Model: Common Carotid Artery to External Jugular Vein Anastomosis.
Published on: January 27, 2015
15:21Training a Sophisticated Microsurgical Technique: Interposition of External Jugular Vein Graft in the Common Carotid Artery in Rats
Published on: November 11, 2012
Related Concept Videos
Collar Bearings
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Internal Receptors
Internal Energy
Support Reactions in Three Dimensions
Ball and Socket Joint is one of the supports allowing free rotation about any axis. This freedom of rotation is...
Relative Velocity in One Dimension