Related Experiment Video
Updated: Feb 6, 2026

Parametric Optimization Design Method for Friction Plates of Hydro-Viscous Clutches
Published on: July 22, 2025
Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and
Uni Wong1,2, Erik B Person1,2, Donald O Castell3
1Division of Gastroenterology and Hepatology, University of Maryland School of Medicine, Baltimore, MD, USA.
Background/Aims:
Swallows with viscous or solid boluses in different body positions alter esophageal manometry patterns. Limitations of previous studies include lack of standardized viscous substrates and the need for chewing prior to swallowing solid boluses. We hypothesize that high-resolution impedance manometry (HRiM) using standardized viscous and super-viscous swallows in supine and upright positions improves sensitivity for detecting esophageal motility abnormalities when compared with traditional saline swallows. To establish normative values for these novel substrates, we recruited healthy volunteers and performed HRiM.
Methods:
Standardized viscous and super-viscous substrates were prepared using "Thick-It" food thickener and a rotational viscometer. All swallows were administered in 5-mL increments in both supine and upright positions. HRiM metrics and impedance (bolus transit) were calculated. We used a paired two-tailed t test to compare all metrics by position and substrate.
Results:
The 5-g, 7-g, and 10-g substrates measured 5000, 36 200, and 64 700 mPa∙sec, respectively. In 18 volunteers, we observed that the integrated relaxation pressure was lower when upright than when supine for all substrates (P < 0.01). The 10-g substrate significantly increased integrated relaxation pressure when compared to saline in the supine position (P < 0.01). Substrates and positions also affected distal contractile integral, distal latency, and impedance values.
Conclusions:
We examined HRiM values using novel standardized viscous and super-viscous substrates in healthy subjects for both supine and upright positions. We found that viscosity and position affected HRiM Chicago metrics and have potential to increase the sensitivity of esophageal manometry.
Related Concept Videos
Super-resolution Fluorescence Microscopy
Pilot and Numeric Relaying
Impedance Combination
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Position-effect Variegation
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...

