Related Experiment Video
Updated: Feb 6, 2026

Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Additively manufactured versus conventionally pressed cranioplasty implants: An accuracy comparison
Sean Peel1, Dominic Eggbeer1, Hanna Burton1
11 PDR - International Centre for Design & Research, Cardiff Metropolitan University, Cardiff, UK.
Abstract:
This article compared the accuracy of producing patient-specific cranioplasty implants using four different approaches. Benchmark geometry was designed to represent a cranium and a defect added simulating a craniectomy. An 'ideal' contour reconstruction was calculated and compared against reconstructions resulting from the four approaches -'conventional', 'semi-digital', 'digital - non-automated' and 'digital - semi-automated'. The 'conventional' approach relied on hand carving a reconstruction, turning this into a press tool, and pressing titanium sheet. This approach is common in the UK National Health Service. The 'semi-digital' approach removed the hand-carving element. Both of the 'digital' approaches utilised additive manufacturing to produce the end-use implant. The geometries were designed using a non-specialised computer-aided design software and a semi-automated cranioplasty implant-specific computer-aided design software. It was found that all plates were clinically acceptable and that the digitally designed and additive manufacturing plates were as accurate as the conventional implants. There were no significant differences between the additive manufacturing plates designed using non-specialised computer-aided design software and those designed using the semi-automated tool. The semi-automated software and additive manufacturing production process were capable of producing cranioplasty implants of similar accuracy to multi-purpose software and additive manufacturing, and both were more accurate than handmade implants. The difference was not of clinical significance, demonstrating that the accuracy of additive manufacturing cranioplasty implants meets current best practice.
Related Concept Videos
Improving Translational Accuracy
Conjugate Addition (1,4-Addition) vs Direct Addition (1,2-Addition)
Conjugate addition results in a thermodynamically stable product. The reaction retains the stronger C=O bond at the expense of the weaker C=C π bond. The process is slow as the β carbon is less electrophilic than the carbonyl carbon.
Direct addition products are...
Uncertainty in Measurement: Accuracy and Precision
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Accuracy and Precision
Steel Manufacturing
During this smelting process, limestone plays a crucial role by forming slag. Slag captures impurities within the molten iron, such...