Reduced Contrast Volume and Radiation Dose During Computed Tomography of the Pancreas: Timing-Specific Contrast Media
Charbel Saade1, Jad Chokr1, Lena Naffaa1
1Diagnostic Radiology Department, American University of Beirut Medical Center, P.O. Box: 11-0236 Riad El-Solh, Beirut 1107 2020, Lebanon.
Rationale And Objective:
To investigate the opacification of the pancreatic vasculature and parenchyma during computed tomography utilizing a patient-specific contrast formula.
Materials And Methods:
This hybrid prospective and retrospective study was approved by the institution review board. In 220 consecutive patients, pancreatic CT was performed with one of two protocols: protocol A, 100mL of contrast material injected via timed bolus triggering technique; or protocol B, employing a patient-specific contrast media protocol specifically timed at the gastroduodenal artery; both protocols employed 4.5 mL/s contrast media and 100mL saline chaser. Attenuation of pancreatic parenchymal, arterial, and venous vasculature supplying the pancreas was measured. Effective dose was calculated. Data were compared to the independent two-sample t test. Receiver operating characteristic, visual grading characteristic, and Cohens' kappa analyses were performed.
Results:
Mean pancreatic density measurements in each of the pancreatic segments during the arterial and venous phase were significantly higher in Protocol B (mean ± standard deviation, art: 96.59 HU ± 27.37; venous: 91.28 HU ± 20.88) compared to A (art: 77.86 HU ± 21.14; venous: 73.99 HU ± 14.75) (p < 0.0001). Mean arterial opacification was significantly higher in protocol B compared to A with the abdominal aorta (p < 0.007), superior mesenteric (p < 0.0002), gastroduodenal (proximal segment only p < 0.014), and splenic arteries (p < 0.036). In the venous circulation, the inferior vena cava, superior mesenteric, portal and splenic veins (all segments) demonstrated significant reduction in vascular opacification protocol B compared to A (p < 0.001). The contrast media volume in protocol B (57.60 ± 12.25 mL) was significantly lower than in protocol A (100 ± 1 mL) (p < 0.001). Effective dose was significantly reduced in protocol B (2.75 ± 0.63 mSv) compared to A (4.015 ± 0.89 mSv) (p < 0.001). Receiver operating characteristic and visual grading characteristic analysis demonstrated significantly higher area under the curve for protocol B (p < 0.0001) (p < 0.034) respectively, with inter-reader agreement increasing from good to excellent in pancreatic lesion detection.
Conclusion:
Timing-specific contrast media protocol enhances image quality at reduced contrast volume and radiation dose during computed tomography of the pancreas.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Biological Effects of Radiation
Imaging Studies III: Computed Tomography
Dose-Response Relationship: Selectivity and Specificity
Pancreas
The broad head of the pancreas lies within the loop formed by the duodenum, while its slender body reaches towards the spleen. The tail of the pancreas is short...