[Effect of autologous blood transfusion device on preventing blood loss in primary total knee arthroplasty using
1Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China.
Objective:
To analyze the conventional application of using comprehensive hemostatic methods during the perioperative period, and the effect of autologous blood transfusion (ABT) device compared with non-negative pressure drainage on preventing blood loss and allogenic blood transfusion after primary total knee arthroplasty (TKA).
Methods:
A total of 131 patients (131 knees) with severe knee osteoarthritis who underwent unilateral primary TKA by the same surgeon in Peking University Third Hospital from June 2014 to June 2015 were enrolled in this study. The patients were divided into ABT group (64 patients) and control group (67 patients). ABT devices were used for drainage and blood transfusion in the ABT group while the control group used the non-negative pressure drainage only. The results of the drainage fluid volume, the decrease of hemoglobin, the total blood loss, the hidden blood loss and blood transfusion after TKA were compared between the two groups.
Results:
The drainage fluid volume in ABT group was significantly higher than that in control group [515 mL (80-1 610 mL) vs. 260 mL (40-670 mL), P<0.001]. The autologous blood transfusion in ABT group was 245 mL (60-1 070 mL). There were no significant differences between the two groups in the value of hemoglobin decrease 1 day after surgery (P=0.340) and 3 days after surgery (P=0.524). There were no significant differences in the total blood loss (P=0.101) and the hidden blood loss (P=0.062) between the two groups either. There were 9 patients in the 131 patients who received allogeneic blood transfusion, of whom 5 in the ABT group (5/64, the blood transfusion rate was 7.8%) and 4 in the control group (4/67, the blood transfusion rate was 6.0%), and no significant differences in the blood transfusion rate between the two groups (P=0.943).
Conclusion:
With the conventional application of using comprehensive hemostatic methods during perioperative period, the ABT device did not show the effective result of controlling postoperative blood loss and failed to reduce the rate of allogeneic blood transfusion in patients with unilateral primary TKA. However, the ABT device could increase the drainage fluid volume and improve the patient's hospitalization expenses. Therefore, there is no need for routine application of ABT device in unilateral primary TKA.
Related Concept Videos
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Composition of Blood
Formed elements constitute the remaining 45% of the blood volume. These...
Blood Flow
Blood Types
ABO blood group
ABO antigens are glycoproteins encoded by genes present on...
Blood Pressure