Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Systematic Error: Methodological and Sampling Errors01:15

Systematic Error: Methodological and Sampling Errors

11.0K
In the case of systematic errors, the sources can be identified, and the errors can be subsequently minimized by addressing these sources. According to the source, systematic errors can be divided into sampling, instrumental, methodological, and personal errors.
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
11.0K
Fundamental Attribution Error01:14

Fundamental Attribution Error

13.8K
According to some social psychologists, people tend to overemphasize internal factors as explanations—or attributions—for the behavior of other people. They tend to assume that the behavior of another person is a trait of that person, and to underestimate the power of the situation on the behavior of others. They tend to fail to recognize when the behavior of another is due to situational variables, and thus to the person’s state. This erroneous assumption is...
13.8K
Nursing Interventions I: Taxonomy of Nursing Interventions01:03

Nursing Interventions I: Taxonomy of Nursing Interventions

3.9K
Nursing interventions are chosen as part of the planning process to achieve patient outcomes. Once nursing diagnoses are determined, the goals and outcomes are specified, then the nursing interventions are selected and individualized according to the patient's situation.
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
3.9K
Nursing Interventions II: Selecting and Classifying the Nursing Interventions01:29

Nursing Interventions II: Selecting and Classifying the Nursing Interventions

3.4K
Creating and executing a nursing diagnosis helps nurses plan care and guide patient, family, and community interventions. They are developed based on a patient's physical evaluation and support measuring the outcomes. It is not recommended to select random interventions throughout the planning process. Instead, consider the following six essential factors when choosing interventions:
3.4K
Random Error01:04

Random Error

9.8K
Random or indeterminate errors originate from various uncontrollable variables, such as variations in environmental conditions, instrument imperfections, or the inherent variability of the phenomena being measured. Usually, these errors cannot be predicted, estimated, or characterized because their direction and magnitude often vary in magnitude and direction even during consecutive measurements. As a result, they are difficult to eliminate. However, the aggregate effect of these errors can be...
9.8K
Margin of Error01:27

Margin of Error

7.6K
The margin of error is also called the maximum error of an estimate. The margin of error is the maximum possible or expected difference between the observed sample parameter value and the actual population parameter value. For proportion, it is the maximum difference between the value of sample proportion obtained from the data and the true value of population proportion. As the true value of the population parameter is not known, the margin of error is calculated using the sample statistic.
7.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Hyperspectral Fingerprints of Abdominal and Pelvic Organs.

Journal of imaging·2026
Same author

Design and technical validation of a low-cost, titanium sheet metal TORP (SM-T) for manufacturing and use in LMICs- ERRATUM.

The Journal of laryngology and otology·2026
Same author

Reference values for fetal heart rate monitoring in a large tertiary hospital population: a retrospective study.

The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians·2026
Same author

Patient-tailored brachytherapy applicator development in compliance with the EU medical device regulation.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
Same author

Skin Tone in Hyperspectral Imaging and Its Implications for Fairness in AI.

Journal of biophotonics·2026
Same author

Design and technical validation of a low-cost, titanium sheet metal TORP (SM-T) for manufacturing and use in LMICs.

The Journal of laryngology and otology·2026

Related Experiment Video

Updated: Feb 6, 2026

Author Spotlight: Enhancing Microinjection Needle Quality by Wet Beveling
06:00

Author Spotlight: Enhancing Microinjection Needle Quality by Wet Beveling

Published on: September 27, 2024

869

Needle placement errors: do we need steerable needles in interventional radiology?

Tonke L de Jong1, Nick J van de Berg1, Lisette Tas1

  • 1BioMechanical Engineering Department, Delft University of Technology, Delft, the Netherlands, T.L.deJong@tudelft.nl.

Medical Devices (Auckland, N.Z.)
|August 21, 2018
PubMed
Summary

Interventional radiologists face challenges with needle placement accuracy due to target motion. Steerable needles are highly desired to improve precision and overcome current limitations in radiologic interventions.

Keywords:
clinical useinterventional radiologyneedle bendingneedle deflectionneedle placement errorquestionnairesteerable needle

More Related Videos

Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules
06:03

Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules

Published on: May 23, 2015

22.9K
Author Spotlight: Fu's Subcutaneous Needling for Knee Osteoarthritis Pain
07:19

Author Spotlight: Fu's Subcutaneous Needling for Knee Osteoarthritis Pain

Published on: March 24, 2023

6.0K

Related Experiment Videos

Last Updated: Feb 6, 2026

Author Spotlight: Enhancing Microinjection Needle Quality by Wet Beveling
06:00

Author Spotlight: Enhancing Microinjection Needle Quality by Wet Beveling

Published on: September 27, 2024

869
Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules
06:03

Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules

Published on: May 23, 2015

22.9K
Author Spotlight: Fu's Subcutaneous Needling for Knee Osteoarthritis Pain
07:19

Author Spotlight: Fu's Subcutaneous Needling for Knee Osteoarthritis Pain

Published on: March 24, 2023

6.0K

Area of Science:

  • Interventional Radiology
  • Medical Device Engineering
  • Surgical Navigation

Background:

  • Accurate needle placement is critical in interventional radiology but challenging due to tissue motion and deformation.
  • Current needle limitations impact procedural success and patient outcomes.

Purpose of the Study:

  • To assess the clinical need for steerable needles in interventional radiology.
  • To identify current challenges in needle placement and allowable error margins.
  • To determine if steerable needles offer added clinical value.

Main Methods:

  • A survey was conducted among 125 interventional radiologists at a European radiology meeting.
  • Respondents reported on challenges, allowable errors, and perceived value of improved needles.

Main Results:

  • Patient movement (90%) is the primary challenge in needle placement.
  • The mean allowable needle placement error is 2.7 mm, with 85% experiencing needle bending (mean 5.3 mm).
  • 95% of radiologists desire needle improvements, and 93% see value in steerable needles.

Conclusions:

  • Steerable needles show significant potential to enhance clinical value in radiologic interventions.
  • Findings can inform the design of advanced tools like steerable needles and navigation systems.