Related Experiment Video
Updated: Feb 6, 2026

Bio-inspired Polydopamine Surface Modification of Nanodiamonds and Its Reduction of Silver Nanoparticles
Published on: November 14, 2018
Surface analysis of gutta percha after disinfecting with sodium hypochlorite and silver nanoparticles by atomic force
Priyesh Mishra1, Sanjeev Tyagi2
1Department of Conservative Dentistry and Endodontics, Purvanchal Institute of Dental Science, Gorakhpur, Uttar Pradesh, India.
Background:
Sodium hypochlorite (5.25% NaOCl) and silver nanoparticles (70 ug/ml AgNPs) have a broad spectrum of antimicrobial efficacy for disinfecting gutta percha (GP) point, so this study was conducted to analyze the assay surface topography of GP when disinfected with AgNPs and 5.25% of NaOCl using atomic force microscopy (AFM).
Materials And Methods:
In this in vitro study a total of thirty cones were taken. The samples were divided into three treatment groups: Group I and II with 70 μg/ml AgNPs and 5.25% NaOCl. The time duration was 1 min. Untreated GP points served as control group. After treatment of 1 min for each solution, the samples were positioned in the AFM. For comparison, the root mean square (RMS) was used to investigate the structure of the GP points. Unpaired t-test and ANOVA test were used. The differences among the groups were tested by Tukey's honestly significant difference test and were considered significant when P < 0.05.
Results:
5.25% NaOCl created RMS value of 202.48 nm at 1 min as compared to 70 μg/ml of AgNPs and control which produced RMS value of 44.48 nm and 24.1 nm, respectively (<0.0001).
Conclusion:
The study showed irregularity in the surface of GP with NaOCl and lesser deterioration with AgNPs which could affect the postoperative prognosis. In this study, it was found that NaOCl causes 10 times more surface topography deterioration of GP when compared to AgNPs at 700 times lesser concentration.
Related Concept Videos
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Intermolecular Forces
Atomic Orbitals
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Hydrostatic Pressure Force on a Plane Surface
Hydrostatic Pressure Force on a Curved Surface