Related Experiment Video
Updated: Feb 6, 2026

08:41
Ultrasound Velocity Measurement in a Liquid Metal Electrode
Published on: August 5, 2015
12.2K
Correction: Variation of the Fermi level and the electrostatic force of a metallic nanoparticle upon colliding with
Pekka Peljo1, José A Manzanares2, Hubert H Girault1
1Laboratoire d'Electrochimie Physique et Analytique (LEPA) , École Polytechnique Fédérale de Lausanne (EPFL) , Rue de l'Industrie 17 , CH-1951 Sion , Switzerland .
Chemical Science
|August 21, 2018
Abstract:
[This corrects the article DOI: 10.1039/C7SC00848A.].
Related Concept Videos
Fermi Level
1.8K
The Fermi-Dirac function is represented by an S-shaped curve indicating the probability of an energy state being occupied by an electron at a given temperature. The Fermi level is the energy level at which there is a fifty percent chance of finding an electron, and it is positioned between the lower-energy valence band and the higher-energy conduction band.
At absolute zero temperature, electrons fill all energy states up to the Fermi level, leaving upper states empty. As the temperature rises,...
At absolute zero temperature, electrons fill all energy states up to the Fermi level, leaving upper states empty. As the temperature rises,...
1.8K
Fermi Level Dynamics
735
The vacuum level denotes the energy threshold required for an electron to escape from a material surface. It is usually positioned above the conduction band of a semiconductor and acts as a benchmark for comparing electron energies within various materials.
Electron affinity in semiconductors refers to the energy gap between the minimum of its conduction band and the vacuum level and it is a critical parameter in determining how easily a semiconductor can accept additional electrons.
The work...
Electron affinity in semiconductors refers to the energy gap between the minimum of its conduction band and the vacuum level and it is a critical parameter in determining how easily a semiconductor can accept additional electrons.
The work...
735
Intermolecular vs Intramolecular Forces
97.4K
Intermolecular forces (IMF) are electrostatic attractions arising from charge-charge interactions between molecules. The strength of the intermolecular force is influenced by the distance of separation between molecules. The forces significantly affect the interactions in solids and liquids, where the molecules are close together. In gases, IMFs become important only under high-pressure conditions (due to the proximity of gas molecules). Intermolecular forces dictate the physical properties of...
97.4K
Intermolecular Forces
71.5K
Atoms and molecules interact through bonds (or forces): intramolecular and intermolecular. The forces are electrostatic as they arise from interactions (attractive or repulsive) between charged species (permanent, partial, or temporary charges) and exist with varying strengths between ions, polar, nonpolar, and neutral molecules. The different types of intermolecular forces are ion–dipole, dipole–dipole, hydrogen bonds, and dispersion; among these, dipole–dipole, hydrogen...
71.5K
What is Variation?
18.6K
Apart from the measures of central tendency, distribution, outliers, and the changing characteristics of data with time, an important characteristic of any data set is its variation or spread. In some data sets, the data values are concentrated closely near the mean; in others, the data values are more widely spread out from the mean.
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
18.6K
Distance Corrections
293
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
293