Related Experiment Video
Updated: Feb 6, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
SecurAcath for Securing Peripherally Inserted Central Catheters: A NICE Medical Technology Guidance
Tom Macmillan1, Mark Pennington2, Jennifer A Summers3
1King's Technology Evaluation Centre, School of Biomedical Engineering and Imaging Sciences, King's College London, 5th Floor, Becket House, 1 Lambeth Palace Road, London, SE1 7EU, UK. thomas.macmillan@kcl.ac.uk.
Abstract:
Central venous catheters are commonly used to deliver therapies and to monitor patients, and require securing at the point of percutaneous entry to avoid dislodgement. SecurAcath is a catheter securement device designed for central venous catheters. The National Institute for Health and Care Excellence, as a part of its Medical Technologies Evaluation Programme, selected this device for evaluation and invited the manufacturer, Interrad Medical, to submit clinical and economic evidence. The King's Technology Evaluation Centre, an External Assessment Centre commissioned by the National Institute for Health and Care Excellence, independently critiqued the manufacturer's submissions. The External Assessment Centre found a lack of evidence comparing SecurAcath with alternative approaches to securement (StatLock, suturing, tape securement), with one unpublished randomised controlled trial providing the strongest evidence. The External Assessment Centre conducted a new systematic review and meta-analysis and concluded that there is some evidence indicating the non-inferiority of SecurAcath compared to StatLock. The External Assessment Centre considered the manufacturer's economic model to be appropriate but made revisions to some parameters and noted significant heterogeneity in the included studies. The revised model indicated that StatLock was more cost effective than SecurAcath for catheter indwell times of up to 5 days; however, for medium- and long-term indwell times, SecurAcath was the most cost-effective option. The National Institute for Health and Care Excellence Medical Technologies Guidance MTG 34, issued in June 2017, recommended the adoption of SecurAcath for securing peripherally inserted central catheters within the National Health Service in England.
Related Concept Videos
Peripherally and Centrally Acting Muscle Relaxants: A Comparison
Centrally acting muscle relaxants can be further divided into spasmolytic and antispasmodic drugs. Spasmolytic...
The Central Dogma
The Central Dogma
RNA is the Missing Link Between DNA and Proteins
In the early 1900s, scientists discovered that DNA stores all the information needed for cellular functions and that proteins perform most of these functions. However, the mechanisms of converting genetic information into functional proteins remained unknown for many years. Initially, it was believed that a single gene is...
Measures of Central Tendency
Inhaled Medications
Hybridoma Technology
Hybridoma Selection
Commonly used fusion techniques — electroporation,...