Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system
Yuki Michinaga1,2, Tamaki Takano3, Takamitsu Terasaki3
11 Department of Cardiovascular Surgery, Shinshu University School of Medicine, Matsumoto, Japan.
Insights
Wall suction demonstrated the lowest hemolysis in vitro and proved effective in clinical trials for the Dihead cardiopulmonary bypass (CPB) system. This suggests wall suction is a feasible option for coronary artery bypass grafting (CABG) surgery.
Area of Science:
- Cardiovascular Surgery
- Biomedical Engineering
- Hemodynamics
Background:
- Developing a closed-circuit cardiopulmonary bypass (CPB) system, "Dihead CPB," for coronary artery bypass grafting (CABG) and valve surgery.
- Minimizing hemolysis is crucial for patient safety during CPB procedures.
Purpose of the Study:
- To compare the hemolysis levels of three different suction systems (roller-pump, SmartSuction, and wall suction) during CPB.
- To evaluate the clinical feasibility and effectiveness of the Dihead CPB system with the optimal suction method.
Main Methods:
- In vitro studies comparing hemolysis and suction speed across roller-pump, SmartSuction, and wall suction systems.
- A clinical study involving 15 volunteers using the Dihead CPB system with wall suction to assess hemolysis and suction adequacy.
Main Results:
- Wall suction exhibited the lowest hemolysis rate (0.41 ± 0.11%) compared to roller suction (0.61 ± 0.10%) and SmartSuction (2.00 ± 0.33%) in vitro (p<0.001).
- SmartSuction provided the fastest suction speed, while wall suction demonstrated efficient performance in the clinical study with no significant increase in plasma free hemoglobin.
Conclusions:
- Wall suction is associated with significantly less hemolysis than roller or SmartSuction systems.
- The Dihead CPB system combined with wall suction is clinically feasible for CABG surgery, offering efficient suction and acceptable hemolysis levels.
Introduction:
We have been developing a closed-circuit cardiopulmonary bypass (CPB) system ("Dihead CPB") for application during coronary artery bypass grafting (CABG) and valve surgery. To strive for minimal hemolysis during Dihead CPB, we compared the hemolysis caused by three different suction systems and performed a clinical study with the newly applied suction system.
Materials & Methods:
We evaluated the hemolysis caused by roller-pump suction, the SmartSuction® Harmony® and wall suction systems with respect to suction speed and compared the systems by means of in vitro studies. A clinical study was also performed on 15 volunteers to assess hemolysis and the adequacy of the newly applied suction system with Dihead CPB.
Results:
Pressure inside the suction cannula was -22.5 ± 0.1 mmHg at a maximum flow of 1.5 L/min for roller-pump suction and -43.4 ± 0.1 mmHg at -150 mmHg of the set vacuum pressure of wall suction. With the SmartSuction, the pressure inside the cannula varied from -76.3 ± 1.0 to -130.3 ± 1.5 mmHg, depending on suctioning conditions. Suction speed (to suction 50 ml of blood) was fastest with the SmartSuction (69.7 ± 3.58 s) whereas, with roller suction, it was 117.3 ± 8.47 s and with wall suction 96.9 ± 7.10 s. The SmartSuction had the highest hemolysis rate (2.00 ± 0.33%) vs. 0.61 ± 0.10% for roller suction and 0.41 ± 0.11% for wall suction (p<0.001). The clinical study with wall suction showed no significant increase in plasma free hemoglobin during or after CPB compared with before surgery.
Conclusions:
Wall suction had less hemolysis than roller suction or the SmartSuction in the in vitro study and the clinical study with wall suction showed efficient suction speed and acceptable hemolysis, suggesting that Dihead CPB with wall suction is feasible for CABG.
Related Concept Videos
Characteristics of Life
Tracheostomy Suctioning II: Procedure
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Cardiopulmonary Resuscitation I: Adult
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...