Comparative Evaluation of Five Different Methods of Anti-ABO Antibody Titration: An Aid for ABO-Incompatible Organ

Sweta Nayak1, Raj Nath Makroo1, Bindu Prakash1

  • 1Transfusion Medicine, Indraprastha Apollo Hospital, New Delhi, India.

Related Concept Videos

The ABO Blood Group01:12

The ABO Blood Group

The ABO blood group system is a critical element of transfusion medicine, essential for determining blood compatibility in transfusions and organ transplants. It is based on specific antigens, or agglutinogens, present on the surface of red blood cells (RBCs) and corresponding antibodies, or agglutinins, in the blood plasma.
Antigens in the ABO Blood Group System
Antigens are substances that can trigger an immune response, leading to the production of antibodies. In the ABO blood group system,...
5.2K
Titration of a Polyprotic Acid02:08

Titration of a Polyprotic Acid

A polyprotic acid contains more than one ionizable hydrogen and undergoes a stepwise ionization process.  If the acid dissociation constants of the ionizable protons differ sufficiently from each other, then the titration curve for such polyprotic acid generates a distinct equivalence point for each of its ionizable hydrogens. Therefore, titration of a diprotic acid results in the formation of two equivalence points, whereas the titration of a triprotic acid results in the formation of three...
105.3K
Acid-Base Titration Curves02:23

Acid-Base Titration Curves

A titration curve is a plot of some solution property versus the amount of added titrant. For acid-base titrations, solution pH is a useful property to monitor because it varies predictably with the solution composition and, therefore, may be used to monitor the titration’s progress and detect its endpoint. Acid-base titration can be performed with a strong acid and a strong base, a strong acid and a weak base, or a strong base and a weak acid.
For a titration carried out for 25.00 mL of...
141.5K
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
6.0K
Titration Calculations: Weak Acid - Strong Base03:55

Titration Calculations: Weak Acid - Strong Base

Calculating pH for Titration Solutions: Weak Acid/Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
49.3K
Comparative Excretory Systems02:24

Comparative Excretory Systems

Animals have evolved different strategies for excretion, the removal of waste from the body. Most waste must be dissolved in water to be excreted, so an animal’s excretory strategy directly affects its water balance.
26.7K