Computed Tomography and Biomechanical Comparison between Trans-Articular Screw Fixation and 2 Polymethylmethacrylate
Guillaume Leblond1, Noël M M Moens1, Luis Gaitero1
1Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.
Objectives:
Canine ventral atlantoaxial stabilization methods have been constantly evolving over the past few decades. Yet, proper experimental data comparing the feasibility and biomechanical properties of currently available surgical options are lacking. The aims of this study were (1) to describe and compare the safety profiles and biomechanical properties of three ventral atlantoaxial stabilization methods; and (2) to test whether recently reported optimal implant definitions constitute reasonable guidelines.
Methods:
Three types of atlantoaxial stabilization including trans-articular screw fixation (TSF) and two cemented constructs (MI5 and MI6) were performed in 21 Beagle cadavers. Post-surgical computed tomography (CT) images of the constructs and biomechanical data were then generated and statistically analysed.
Results:
The CT data revealed that TSF achieved significantly better apposition than cemented constructs. Out of 91 screws positioned, 4.4% were graded as dangerous and 86.8% as optimal. Optimal positioning was most challenging to obtain for mono-cortical screws. Analysis of biomechanical data suggested that all three techniques could likely achieve similar rates of atlantoaxial fusion when submitted to physiological loads but also that cemented constructs were less prone to failure compared with TSF.
Clinical Significance:
This study provides evidence that all three techniques are technically feasible and biomechanically viable but also that the evaluated surgical guidelines could be improved.
More Related Videos
11:09Construction of a Realistic, Whole-Body, Three-Dimensional Equine Skeletal Model using Computed Tomography Data
Published on: February 25, 2021
07:57An Experimental and Finite Element Protocol to Investigate the Transport of Neutral and Charged Solutes across Articular Cartilage
Published on: April 23, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Hydration of Cement
Soundness of Cement
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Screw: Problem Solving
To evaluate the...