Related Experiment Video
Updated: Feb 6, 2026

Rapid Identification of Gram Negative Bacteria from Blood Culture Broth Using MALDI-TOF Mass Spectrometry
Published on: May 28, 2014
Evaluation of the Bruker® MBT Sepsityper IVD module for the identification of polymicrobial blood cultures with
Anaïs Scohy1, Audrey Noël2, Anca Boeras3
1Department of Microbiology, Cliniques universitaires Saint-Luc, Université Catholique de Louvain, Avenue Hippocrate 10, B-1200, Brussels, Belgium. anais.scohy@uclouvain.be.
Abstract:
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) considerably reduces timeframe required from initial blood culture positivity towards complete bacterial identification. However, rapid identification of polymicrobial blood cultures remains challenging. We evaluated the performances of the Bruker® MBT Sepsityper IVD module on MALDI-TOF MS for the direct identification of polymicrobial blood culture bottles. This module has the ability to give a strong indication that a sample contains a mixture of organisms and to identify two of them. Blood culture bottles considered as polymicrobial using routine subculture were collected and processed using the Sepsityper kit. MALDI-TOF MS identification was performed using the MBT Compass IVD software including the Sepsityper module. From 143 polymicrobial blood culture bottles tested, 34.3% (49/143) were completely identified by the module. Both microorganisms were more easily detected by the module in samples containing two pathogens than in samples containing two contaminants (36.8% vs 29.4%). Additionally, in more than half of the samples, the module detected 1 of the different microorganisms contained in the same vial. In these cases, with a pathogen and contaminant in the same sample, the module detected the pathogen in more than 80%. The Sepsityper module identified 14 microorganisms which were not recovered by conventional culture methods. The Bruker® MBT Sepsityper IVD module contributed to a valuable identification of polymicrobial blood cultures in more than a third of all cases. Conventional culture methods are still required to complete the results and to carry on susceptibility testing.
More Related Videos
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-Assisted Laser Desorption Ionization (MALDI)
Methods of Classification and Identification
Self-Evaluation: Self-Enhancement and Self-Verification
Composition of Blood
Formed elements constitute the remaining 45% of the blood volume. These...
Blood Flow