Background:
Data regarding pretreatment, bioimpedance spectroscopy (BIS) L-Dex® values for patients newly diagnosed with breast cancer, and longitudinal data 12 months postoperatively are lacking. This study describes L-Dex values at the time of breast cancer diagnosis and maximum L-Dex change within 12 months of surgery.
Methods And Results:
Patients were enrolled in a parent, clinical trial that compares the effectiveness of BIS for early detection of breast cancer-related lymphedema to tape measurement. A total of 280 women with a pretreatment and at least one postoperative L-Dex measurement (within 12 months of surgery) were included. Pretreatment L-Dex readings were compared with population norms and maximum L-Dex changes within 12 months were examined. An L-Dex U400 device was used to obtain BIS measurements. The documented normative mean value using this device is 0.00, which is at the 49th percentile for this sample. Approximately 6% of patients had a pretreatment L-Dex value of ≥7.0; 1.8% had an L-Dex value ≥10.0. For 12 months, 17.1% (n = 48) of patients had a maximum change in L-Dex value from pretreatment of ≥7.0 L-Dex units, suggestive of clinical lymphedema.
Conclusions:
At the time of breast cancer diagnosis, L-Dex values are similar to normative values. Identified maximum changes in L-Dex values 12 months postoperatively suggest that frequent L-Dex measurements during that time frame are of potential clinical benefit. Our findings are consistent with research supporting an L-Dex value of ≥7 as indicative of clinical lymphedema with subclinical lymphedema logically occurring at somewhat lower likely, near ≥6.5.
Related Concept Videos
Biodiversity and Human Values
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...
Critical Values
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...
Absolute and Local Extreme Values
Mouse Models of Cancer Study
The development of transgenic, knockout, and knock-in mice has led to an exponential increase in their use as model organisms in research,...