Related Experiment Video
Updated: Feb 6, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Quantitative analysis of susceptibility-weighted magnetic resonance imaging in chronic hepatitis in rats
Yu Cai1, Meng-Ping Huang1, Xiao-Feng Wang1
1Department of Radiology, The Affiliated Hospital of Southwest Medical University, People's Republic of China.
Purpose:
To assess the value of susceptibility-weighted imaging (SWI) for staging of liver fibrosis (F), necroinflammatory activity (A), and steatosis (S) of chronic hepatitis.
Methods:
100 Sprague-Dawley (SD) male rats were randomly divided into a chronic hepatitis model group (n = 88) and a control group (n = 12). The chronic hepatitis model rats were induced by intraperitoneal injection of 40% (v/v) of carbon tetrachloride (CCl4) diluted in olive oil. All rats were examined by magnetic resonance imaging (MRI) and then killed immediately to detect pathologic staging as liver fibrosis (F), necroinflammatory activity (A), and steatosis (S). Liver-to-muscle signal intensity ratios (SIRs) of SWI were analyzed and associated with histopathologic findings.
Results:
There were ultimately 11 normal control rats and 60 chronic hepatitis model rats. Statistical data were as follows: F0 (n = 11), F1 (n = 18), F2 (n = 16), F3 (n = 13), F4 (n = 13); A0 (n = 11), A1 (n = 29), A2 (n = 21), A3 (n = 10); S0 (n = 11), S1 (n = 12), S2 (n = 12), S3 (n = 18), and S4 (n = 18). The liver-to-muscle SIR of the SWI was related to hepatic fibrosis (P < 0.05) and liver steatosis (P < 0.05) but not to necroinflammatory activity (P > 0.05). By partial correlation analysis, a significant negative correlation was shown between the liver-to-muscle SIR and staging of liver fibrosis (r = -0.68, P < 0.05) as well as a low correlation with liver steatosis (r = 0.30, P < 0.05). Except for F0-F1 and F1-F2, there were statistical differences between each of the stages of hepatic fibrosis (P < 0.05), with an area under the ROC of 0.87 for F3 or above and of 0.96 for F4.
Conclusion:
SWI can be a reliable method for staging hepatic fibrosis.
Related Concept Videos
Magnetic Resonance Imaging
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Imaging Studies IV: Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...

