Computational quantitative flow ratio to assess functional severity of coronary artery stenosis
Daan Ties1, Randy van Dijk1, Gabija Pundziute2
1University of Groningen, University Medical Center Groningen, Center for Medical Imaging, Groningen, The Netherlands; University of Groningen, University Medical Center Groningen, Department of Cardiology, Groningen, The Netherlands.
Abstract:
Background Computational quantitative flow ratio (QFR) based on 3-dimensional quantitative coronary angiography (3D QCA) analysis offers the opportunity to assess the significance of coronary artery disease (CAD) without using an invasive pressure wire or inducing hyperemia. This study aimed to evaluate the diagnostic performance of QFR compared to wire-based fractional flow reserve (FFR) and to validate the previously reported QFR cut-off value of >0.90 to safely rule out functionally significant CAD. Methods QFR was retrospectively derived from standard-care coronary angiograms. Correlation and agreement of fixed-flow QFR (fQFR) and contrast-flow QFR (cQFR) models with invasive wire-based FFR was calculated. Diagnostic performance of QFR was evaluated at different QFR cut-off values defining significant CAD (FFR ≤ 0.80). Results 101 vessels in 96 patients who underwent FFR were studied. Mean FFR was 0.87 ± 0.08 and 21 of 101 (21%) vessels had an FFR ≤ 0.80. Correlation of fQFR and cQFR with FFR was r = 0.71 (p < 0.001) and r = 0.70 (p < 0.001), respectively. Sensitivity and specificity were 57% and 93% for fQFR and 67% and 96% for cQFR at a QFR cut-off value >0.80 defining non-significant CAD, respectively. fQFR > 0.90 was present in 34 (34%) and cQFR > 0.90 in 39 (39%) vessels. For both QFR models, none of the vessels with QFR > 0.90 had an FFR ≤ 0.80. Conclusions QFR appears to be a safe and effective gatekeeper to wire-based FFR when applying a QFR threshold of >0.90 to rule out significant CAD. Further prospective research is required to establish QFR in the real-life setting of functional CAD assessment in the catheterization laboratory.
More Related Videos
04:40Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
Coronary Artery Disease I: Introduction
Coronary Artery Disease II: Pathophysiology
Coronary Artery Disease V: Interprofessional Care
Coronary Artery Disease III: Clinical Manifestations
Coronary Artery Disease IV: Preventive Measures
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...