Aim:
The aim of the present study is to compare the amount of remaining calculus, loss of tooth substance, and roughness of root surface after scaling and root planing with or without magnification loupes using scanning electron microscope.
Materials And Methods:
In the study, 30 teeth indicated for extractions due to severe chronic generalized periodontitis were included in the study. In test Group I, scaling and root planing was performed without magnification loupes, and in test Group II, scaling and root planing was performed with magnification loupes before extraction. In control Group III, no procedure was performed. After scaling and root planing, teeth were extracted followed by preparation of specimens. Specimens were then sent for scanning electron microscope study.
Results:
Statistically significant (P ≤ 0.05) differences were found among different test groups. Results showed that test Group II with magnification loupes had less remaining calculus and smoother surface with lesser amount of loss of cementum layer.
Conclusion:
From this, it was concluded that test Group II was more efficient in root debridement than test Group 1, so scaling and root planing done with magnification loupes will cause less damage to the tooth surface.
More Related Videos
11:14Comprehensive Characterization of Extended Defects in Semiconductor Materials by a Scanning Electron Microscope
Published on: May 28, 2016
10:25Single-Digit Nanometer Electron-Beam Lithography with an Aberration-Corrected Scanning Transmission Electron Microscope
Published on: September 14, 2018
Related Concept Videos
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Pilot and Numeric Relaying
pH Scale
Work Done Over an Inclined Plane
The work done by gravity to move a rigid body, or the work done by an opposing force to move a rigid body against gravity, can be calculated using the center-of-mass framework. It is the line integral of the force of gravity over the path, considered positive if...
Leaky Scanning