Related Experiment Video
Updated: Feb 6, 2026

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Structures at Risk During Percutaneous Screw Fixation for Talonavicular Fusion
Sung Ro Lee1, Davis Stibolt1, Harshadkumar Patel1
11 University of Alabama at Birmingham, Birmingham, AL, USA.
Background::
Talonavicular (TN) fusion using screws dorsomedially and dorsolaterally can cause neurovascular injury. The purpose of our cadaveric study was to evaluate the safety of percutaneous screw insertion in relation to dorsal neurovascular structures.
Methods::
Ten fresh-frozen cadaver legs were used for this study. Percutaneous cannulated screws were inserted to perform isolated TN arthrodesis. The screws were inserted at 3 consistent sites: a "medial screw" at the dorsomedial navicular where it intersected at the medial plane of the first cuneiform, a "central screw" at the edge of the dorsal navicular between the medial and intermediate cuneiforms, and a "lateral screw" at the edge of the dorsal navicular between the intermediate and lateral cuneiforms. Superficial and deep dissections were carried out to identify any injured nerves, arteries, and/or tendons.
Results::
The medial screw injured the anterior tibialis tendon in 2 cases (20%), the central screw injured the extensor hallucis longus tendon in 3 cases (30%), and the lateral screw injured the anterior branch of the superior peroneal nerve (SPN), the lateral branch of the SPN, and the medial branch of the distal peroneal nerve (DPN) once each in a total of 3 cases (30%). Despite no direct injury, the central screw indicated a potential risk of neurovascular injury: closest distance to the anterior SPN was 2 mm and to the medial DPN 2 mm.
Conclusion::
Although neurovascular injury risk exists for all of these screw placements, TN fusion with a central screw introduced a potentially decreased risk of neurovascular injury at the expense of increased risk of tendon injury compared to the lateral screw.
Clinical Relevance::
Based on these results, we recommend a careful dissection be performed prior to percutaneous screw insertion.
More Related Videos
Related Concept Videos
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Relative Risk
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...