Related Experiment Video
Updated: Feb 6, 2026

Biaxial Basal Tone and Passive Testing of the Murine Reproductive System Using a Pressure Myograph
Published on: August 13, 2019
Anisotropy of the Passive and Active Rat Vagina Under Biaxial Loading
Alyssa Huntington1, Emanuele Rizzuto1,2, Steven Abramowitch3
1STRETCH Laboratory, 330A Kelly Hall, 325 Stanger Street, Virginia Tech, Blacksburg, VA, 24061, USA.
Abstract:
Pelvic organ prolapse, the descent of the pelvic organs from their normal anatomical position, is a common condition among women that is associated with mechanical alterations of the vaginal wall. In order to characterize the complex mechanical behavior of the vagina, we performed planar biaxial tests of vaginal specimens in both the passive (relaxed) and active (contracted) states. Specimens were isolated from virgin, female Long-Evans rats (n = 16) and simultaneously stretched along the longitudinal direction (LD) and circumferential direction (CD) of the vagina. Tissue contraction was induced by electric field stimulation (EFS) at incrementally increasing values of stretch and, subsequently, by KCl. On average, the vagina was stiffer in the CD than in the LD (p < 0.001). The mean maximum EFS-induced active stress was significantly higher in the CD than in the LD (p < 0.01). On the contrary, the mean KCl-induced active stress was lower in the CD than in the LD (p < 0.01). When comparing the mean maximum EFS-induced active stress to the mean KCl-induced active stress, no differences were found in the CD (p = 0.366) but, in the LD, the mean active stress was much higher in response to the KCl stimulation (p < 0.001). Collectively, these results suggest that the anisotropic behavior of the vaginal tissue is determined not only by collagen and smooth muscle fiber organization but also by the innervation.
Related Concept Videos
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Vagina
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Passive Diffusion: Overview and Kinetics
When administered orally, drugs establish a substantial concentration gradient between the gastrointestinal (GI) lumen and the bloodstream, expediting...
Impact Loading
In cases of elastic deformation,...
Distributed Loads
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...

