Related Experiment Video
Updated: Feb 6, 2026

Chinese Herbal Retention Enema for the Treatment of Ulcerative Colitis
Published on: May 16, 2025
Establishing content validity and fidelity of a novel paediatric intussusception air enema reduction simulator
Ramesh M Nataraja1,2, Stephanie Khoo3, Michael Ditchfield3
1Department of Paediatric Surgery, Urology and Surgical Simulation, Monash Children's Hospital, Melbourne, Victoria, Australia.
Background:
Intussusception is a common, potentially life-threatening paediatric condition. Non-operative treatment with an air enema has been established as the clinical gold standard. There is no validated model for the training of this procedure. Our aim was to produce a novel air enema reduction simulator and validate its use as a training tool.
Methods:
A low-cost paediatric intussusception air enema simulator was created. It was designed to include essential key clinical procedural steps. Participants included both procedural experts and novices from the Departments of Paediatric Radiology and Surgery. The simulator was assessed for face and content validity and its physical, conceptual and experiential fidelity by a structured questionnaire using a 5-point Likert's scale. Statistical analysis included a t-test, and a P-value of <0.05 was considered significant.
Results:
Twenty-four clinicians completed the simulation activity (expert: 13 and novices: 11). All experts had performed a minimum of 40 clinical procedures, and 46% had performed >50 procedures. All scores were favourable in all domains for face and content validity: 3.5 (physical appearance), 3.3 (insertion of the tube and taping), 3.1 (holding of the buttocks) and 3.5 (performing the air enema). The simulator also scored highly with fidelity assessment; visual 3.5, conceptual 3.4. There was no difference in procedural confidence with experts (3.8 versus 3.6, P = 0.28), but there was for novices (1.0 versus 2.9, P = 0.0002).
Conclusions:
This low-cost air enema reduction simulator for intussusception has an excellent educational potential for use in a training program in a tertiary centre, as well as, resource-constrained environments.
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Reliability and Validity
Oxidation-Reduction Reactions
Stereotype Content Model
Data Validation
Key parameters for method validation include: