Related Experiment Video
Updated: Feb 6, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
[Identification of dalbergia odorifera and dalbergia spp by solid phase microextraction-gas chromatography-mass
Sirun Hou1, Xiaolan Huang1, Yanfang Ma1
1Guangdong Institute of Analysis, Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals, Guangzhou 510070, China.
Abstract:
In addition to species identification, the volatile components of dalbergia odorifera and dalbergia spp, were investigated by solid phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS). Small amounts of powder samples were acquired by drilling from dalbergia, then the volatile components of the powder samples were concentrated by SPME, and separated by AB-FFAP polar capillary GC column. Of all the volatile components, twenty types were identified, and two pairs of them, 2-(1,1-dimethylethyl)-5-heptyl-5-methyl-1,3-dioxolan-4-one and 2,6,10-trimethyl-7,10-epoxy-2,11-dodecadien-6-ol, 2-methylbutylidene-cyclopentane and 2-(5-methyl-furan-2-yl)-propionaldehyde, could be considered specific volatile components for the identification of dalbergia odorifera and dalbergia spp, and the relative contents of these two pairs were compared for the species identification analysis. The method has the advantages of less sample requirement, simple operation, and no construction damage. The method is suitable for the research of volatile components and species identification analysis of dalbergia odorifera and dalbergia spp, and has broad prospective application in the analysis of furniture, art collections and raw wood of dalbergia.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II