Related Experiment Video
Updated: Feb 6, 2026

Deep Vascular Imaging in the Eye with Flow-Enhanced Ultrasound
Published on: October 4, 2021
Adaptive Multifocus Beamforming for Contrast-Enhanced-Super-Resolution Ultrasound Imaging in Deep Tissue
Abstract:
Contrast-enhanced-super-resolution ultrasound imaging, also referred to as ultrasound localization microscopy, can resolve vessels that are smaller than the diffraction limit and has recently been able to generate super-resolved vascular images of shallow in vivo structures in small animals. To fully translate this technology to the clinic, it is advantageous to be able to detect microbubbles at deeper locations in tissue while maintaining a short acquisition time. Current implementations of this imaging method rely on plane-wave imaging. This method has the advantage of maximizing the frame rate, which is important due to the large amount of frames required for super-resolution processing. However, the wide planar beam used to illuminate the field of view produces poor contrast and low sensitivity bubble detection. Here, we propose an "adaptive multifocus" sequence, a new ultrasound imaging sequence that combines the high frame rate feature of a plane wave with the increased bubble detection sensitivity of a focused beam. This sequence simultaneously sonicates two or more foci with a single emission, hence retaining a high frame rate, yet achieving improved sensitivity to microbubbles. In the limit of one target, the beam reduces to a conventional focused transmission; and for an infinite number of targets, it converges to plane-wave imaging. Numerical simulations, using the full-wave code, are performed to compare the point spread function of the proposed sequence to that generated by the plane-wave emission. Our numerical results predict an improvement of up to 15 dB in the signal-to-noise ratio. Ex vivo experiments of a tissue-embedded microtube phantom are used to generate super-resolved images and to compare the adaptive beamforming approach to plane-wave imaging. These experimental results show that the adaptive multifocus sequence successfully detects 744 microbubble events at 60 mm when they are undetectable by the plane-wave sequence under the same imaging conditions. At a shallower depth of 44 mm, the proposed adaptive multifocus method detects 6.9 times more bubbles than plane-wave imaging (1763 versus 257 bubble events).
Related Concept Videos
Super-resolution Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Self-Evaluation: Self-Enhancement and Self-Verification
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement

