Related Experiment Video
Updated: Feb 6, 2026

Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
Modified- versus immediate-release tofacitinib in Japanese rheumatoid arthritis patients: a randomized, phase III,
Yoshiya Tanaka1, Naonobu Sugiyama2, Shigeyuki Toyoizumi2
1The First Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan.
Objective:
Tofacitinib is an oral Janus kinase inhibitor for treatment of RA. We compared tofacitinib modified-release (MR) 11 mg once daily (QD) with tofacitinib immediate-release (IR) 5 mg twice daily (BID) in Japanese patients with RA and inadequate response to MTX.
Methods:
Phase III, randomized, double-blind, double-dummy, 12-week study. Patients were randomized to tofacitinib MR 11 mg QD (n = 104) or IR 5 mg BID (n = 105), with stable MTX. Compliance was based on returned pill counts. The primary objective was to demonstrate non-inferiority of MR 11 mg QD to IR 5 mg BID. Non-inferiority was declared if the upper bound of the two-sided 95% CI for the difference in change from baseline in DAS28-4(CRP) at week 12 was <0.6.
Results:
At week 12, with tofacitinib MR 11 mg QD and IR 5 mg BID, respectively, the change from baseline in least squares mean DAS28-4(CRP) was -2.43 and -2.85; the mean difference was 0.43 (95% CI 0.17, 0.69). Non-inferiority of MR 11 mg QD to IR 5 mg BID was not met. Improvement of DAS28-4(CRP) ⩾1.2 was observed in 89 and 85% of patients, respectively, corresponding to a clinically important, significant change in both groups. The frequency of adverse events (52.9 and 51.4%, respectively) and serious adverse events (4.8 and 3.8%, respectively) was generally similar between treatments. No deaths were reported.
Conclusion:
Non-inferiority of MR 11 mg QD to IR 5 mg BID was not met in this study. However, clinically meaningful improvements in RA were observed with both tofacitinib formulations in Japanese patients. The safety profile was similar with both formulations.
Trial Registration:
ClinicalTrials.gov, http://clinicaltrials.gov, NCT02281552.
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...