Characteristics of Radiofrequency Catheter Ablation Lesion Formation in Real Time In Vivo Using Near Field Ultrasound
Matthew Wright1, Erik Harks2, Szabolcs Deladi2
1Division of Imaging Sciences and Biomedical Engineering, King's College London, United Kingdom and Department of Cardiology, St. Thomas' Hospital, London, United Kingdom.
Objectives:
Visualizing myocardium with near field ultrasound (NFUS) transducers in the tip of the catheter might provide an image of the evolving pathological lesion during energy delivery.
Background:
Radiofrequency (RF) catheter ablation has been effective in arrhythmia treatment, but no technology has allowed lesion formation to be visualized in real time in vivo.
Methods:
RF catheter ablations were performed in vivo with the goal to create transmural atrial lesions and large ventricular lesions. RF lesion formation was imaged in real time using M-mode, tissue Doppler, and strain rate information from the NFUS open irrigated RF ablation catheter incorporating 4 ultrasound transducers (1 axial and 3 radial), and growth kinetics were analyzed. Nineteen dogs underwent ablation in the right and left atria (n = 185), right ventricle (n = 67), and left ventricle (n = 66). Lesions were echolucent with tissue strain rate by NFUS.
Results:
Lesion growth frequently progressed from epicardium to endocardium in thin-walled tissue. The half time of lesion growth was 5.5 ± 2.8 s in thin-walled and 9.7 ± 4.3 s in thick-walled tissue. Latency of lesion onset was seen in 57% of lesions ranging from 1 to 63.8 s. Tissue edema (median 25% increased wall thickness) formed immediately upon lesion formation in 83%, and intramyocardial steam was seen in 71% of cases.
Conclusions:
NFUS was effective in imaging RF catheter ablation lesion formation in real time. It was useful in assessing the dynamics of lesion growth and could visualize impending steam pops. It may be a useful technology to improve both safety and efficacy of RF catheter ablation.
More Related Videos
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
10:21A Coregistered Ultrasound and Photoacoustic Imaging Protocol for the Transvaginal Imaging of Ovarian Lesions
Published on: March 3, 2023
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Characteristics of Life
Characteristics of Fluids
Characteristics of Fluids
Fluids, which include both liquids and gases, are substances that deform continuously under shearing stress. For example, water and oil are liquids with molecules that can...
Characteristics of BJT
For input characteristics, the base-emitter voltage is varied, maintaining a constant collector-emitter voltage. This setup reveals a Shockley-type dependence of the collector current on...
Characteristics of JFET
The core of a JFET's operation is controlling drain current by modulating the gate-source voltage. When the drain and gate voltage are set to zero, the JFET exhibits no net current flow, representing a state of equilibrium. The drain current increases linearly as the...