Related Experiment Video
Updated: Feb 6, 2026

Assessment of Cardiac Function and Myocardial Morphology Using Small Animal Look-locker Inversion Recovery SALLI MRI in Rats
Published on: July 19, 2013
Structural and functional cardiac profile after prolonged duration of mechanical unloading: potential implications
Estibaliz Castillero1, Ziad A Ali2, Hirokazu Akashi1
1Division of Cardiothoracic Surgery, College of Physicians and Surgeons of Columbia University , New York, New York.
Abstract:
Clinical and experimental studies have suggested that the duration of left ventricular assist device (LVAD) support may affect remodeling of the failing heart. We aimed to 1) characterize the changes in Ca2+/calmodulin-dependent protein kinase type-IIδ (CaMKIIδ), growth signaling, structural proteins, fibrosis, apoptosis, and gene expression before and after LVAD support and 2) assess whether the duration of support correlated with improvement or worsening of reverse remodeling. Left ventricular apex tissue and serum pairs were collected in patients with dilated cardiomyopathy ( n = 25, 23 men and 2 women) at LVAD implantation and after LVAD support at cardiac transplantation/LVAD explantation. Normal cardiac tissue was obtained from healthy hearts ( n = 4) and normal serum from age-matched control hearts ( n = 4). The duration of LVAD support ranged from 48 to 1,170 days (median duration: 270 days). LVAD support was associated with CaMKIIδ activation, increased nuclear myocyte enhancer factor 2, sustained histone deacetylase-4 phosphorylation, increased circulating and cardiac myostatin (MSTN) and MSTN signaling mediated by SMAD2, ongoing structural protein dysregulation and sustained fibrosis and apoptosis (all P < 0.05). Increased CaMKIIδ phosphorylation, nuclear myocyte enhancer factor 2, and cardiac MSTN significantly correlated with the duration of support. Phosphorylation of SMAD2 and apoptosis decreased with a shorter duration of LVAD support but increased with a longer duration of LVAD support. Further study is needed to define the optimal duration of LVAD support in patients with dilated cardiomyopathy. NEW & NOTEWORTHY A long duration of left ventricular assist device support may be detrimental for myocardial recovery, based on myocardial tissue experiments in patients with prolonged support showing significantly worsened activation of Ca2+/calmodulin-dependent protein kinase-IIδ, increased nuclear myocyte enhancer factor 2, increased myostatin and its signaling by SMAD2, and apoptosis as well as sustained histone deacetylase-4 phosphorylation, structural protein dysregulation, and fibrosis.
More Related Videos
09:15Displacement Analysis of Myocardial Mechanical Deformation DIAMOND Reveals Segmental Heterogeneity of Cardiac Function in Embryonic Zebrafish
Published on: February 6, 2020
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Mechanical Protein Functions
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Mechanism of Cardiac Arrhythmias
Structural Protein Function
Collagen, the most abundant protein in mammals, is found throughout the body. In connective tissue, such as skin, ligaments, and tendons, it provides tensile strength and elasticity. In bones and teeth, it mineralizes to...
Structure of Cardiac Muscles
Compared to skeletal muscles, cardiac muscle cells are small and mostly have a single nucleus. Additionally, they are usually...
Fruit Development, Structure, and Function