Related Experiment Video
Updated: Feb 6, 2026

Rare Event Detection Using Error-corrected DNA and RNA Sequencing
Published on: August 3, 2018
Radiologist Performance in the Detection of Pulmonary Embolism: Features that Favor Correct Interpretation and Risk
Seth J Kligerman1, Jason W Mitchell2, Jacob W Sechrist3
1Department of Radiology, UUCSD, San Diego, CA.
Purpose:
This study aimed to assess the factors contributing toward accurate detection and erroneous interpretation of pulmonary embolism (PE).
Materials And Methods:
Over 13 months, all computed tomography pulmonary angiography studies were retrospectively rereviewed by a chest radiologist. Two additional chest radiologists assessed cases with disagreement between the first interpretation and rereview. The number, extent, and location of PE and specialty training, experience, time of study, kV, resident prelim, use of iterative reconstruction, signal to noise ratio (SNR), and reports describing the study as "limited" were recorded. Parametric and nonparametric statistical testing was performed (significance P<0.05).
Results:
Of 2555 computed tomography pulmonary angiography cases assessed, there were 230 true positive (170 multiple, 60 single PE), 2271 true negative, 35 false-negative (15 multiple and 20 single PE), and 19 false-positive studies. The overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of radiologists was 86.8%, 99.2%, 92.4%, 98.5%, and 97.9%. Sensitivity for the detection of multiple and central PE was significantly higher than the detection of single and peripheral PE, respectively (P<0.01 for both). The sensitivity of thoracic radiologists (91.7%) was higher than nonthoracic (82.8%) and reached significance for single PE (89.2% vs. 61.4%, P<0.02). Errors were more likely in cases with lower SNR (P=0.04) and those described as limited (P<0.001). Misses occurred more frequently in the upper lobe posterior and lower lobe lateral segments and subsegments (P=0.038).
Conclusions:
The accuracy for PE detection is high, but errors are more likely in studies with single PE interpreted by nonthoracic radiologists, especially when located in certain segments and in cases with low SNR or described as limited.
Related Concept Videos
Pulmonary Embolism I: Introduction
Power Factor Correction
NMR Spectrometers: Resolution and Error Correction
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Pulmonary Embolism III: Nursing Management
Fundamental Attribution Error