Related Experiment Video
Updated: Feb 6, 2026

Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
3D mapping of the placenta during early gestation using free-breathing multiecho stack-of-radial MRI at 3T
Tess Armstrong1,2, Dapeng Liu1, Thomas Martin1,2
1Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA.
Background:
Multiecho gradient-echo Cartesian MRI characterizes placental oxygenation by quantifying . Previous research was performed at 1.5T using breath-held 2D imaging during later gestational age (GA).
Purpose:
To evaluate the accuracy and repeatability of a free-breathing (FB) 3D multiecho gradient-echo stack-of-radial technique (radial) for placental mapping at 3T and report placental during early GA.
Study Type:
Prospective.
Population:
Thirty subjects with normal pregnancies and three subjects with ischemic placental disease (IPD) were scanned twice: between 14-18 and 19-23 weeks GA.
Field Strength:
3T.
Sequence:
FB radial.
Assessment:
Linear correlation (concordance coefficient, ρc ) and Bland-Altman analyses (mean difference, MD) were performed to evaluate radial mapping accuracy compared to Cartesian in a phantom. Radial mapping repeatability was characterized using the coefficient of repeatability (CR) between back-to-back scans. The mean and spatial coefficient of variation (CV) of was determined for all subjects, and separately for anterior and posterior placentas, at each GA range.
Statistical Tests:
ρc was tested for significance. Differences in mean and CV were tested using Wilcoxon Signed-Rank and Rank-Sum tests. P < 0.05 was considered significant. Z-scores for the IPD subjects were determined.
Results:
FB radial demonstrated accurate (ρc ≥0.996; P < 0.001; |MD|<0.2s-1 ) and repeatable (CR<4s-1 ) mapping in a phantom, and repeatable (CR≤4.6s-1 ) mapping in normal subjects. At 3T, placental mean ± standard deviation was 12.9s-1 ± 2.7s-1 for 14-18 and 13.2s-1 ± 1.9s-1 for 19-23 weeks GA. The CV was significantly greater (P = 0.043) at 14-18 (0.63 ± 0.12) than 19-23 (0.58 ± 0.13) weeks GA. At 19-23 weeks, the CV was significantly lower (P < 0.001) for anterior (0.49 ± 0.08) than posterior (0.67 ± 0.11) placentas. One IPD subject had a lower mean than normal subjects at both GA ranges (Z<-2).
Data Conclusion:
FB radial provides accurate and repeatable 3D mapping for the entire placenta at 3T during early GA.
Level Of Evidence:
2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:291-303.
Related Concept Videos
Breathing
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Diabetes Mellitus: Type 2 and Gestational
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Mechanism of Breathing I: Inspiration
The respiratory system, an essential network for breathing, comprises the conducting and respiratory zones, each playing a crucial role in the overall process of respiration. Let us explore the detailed mechanism of inspiration, or inhalation, which is the first phase of the respiratory cycle.
Pathway of Air during Inspiration
During inspiration, air enters our body through the nose or mouth and moves through the conducting zone,...
Mechanism of Breathing II: Expiration
Expiration, or exhaling, is a complex physiological process that begins as the inspiratory muscles begin to relax. This relaxation triggers a series of events that epitomize the efficiency of the respiratory system.
Mechanism of Expiration:

