Concentric Stereotactic Technique of Percutaneous Endoscopic Transforaminal Discectomy and Radiation Exposure to
Guoxin Fan1, Chaobo Feng1, Bangde Yin1
1Orthopedic Department, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China.
Objective:
In percutaneous endoscopic transforaminal discectomy (PETD), surgeons are exposed to intraoperative radiographic radiation over a long-term career, which may be correlated with high risk of iatrogenic radiation hazards. The purpose of this prospective cohort study was to assess the impact of concentric stereotactic technique on radiation exposure to surgeons in PETD.
Methods:
Patients who underwent conventional PETD were regarded as group A, whereas those undergoing PETD with concentric stereotactic technique were considered as group B. The primary outcomes were cumulative radiation dose to the surgeon's eye, thyroid gland, and breast.
Results:
A total of 34 patients were treated in group A and 30 patients were treated in group B. The cumulative radiation dose of the eye per operation was 0.017 (0.58/34) mSv in group A and 0.010 (0.31/30) mSv in group B, which meant a reduction of 41.18%. The cumulative radiation dose of the thyroid gland per operation was 0.018 (0.60/34) mSv in group A and 0.011 (0.33/30) mSv in group B, which meant a reduction of 38.89%. The cumulative radiation dose of the chest per operation was 0.039 (1.33/34) mSv in group A and 0.023 (0.70/30) mSv in group B, which meant a reduction of 41.03%. There were no significant differences in hospital stay, visual analog scale score of waist and leg pain, Oswestry Disability Index score, MacNab satisfaction, and complications between the 2 groups (P > 0.05).
Conclusions:
The concentric stereotactic technique can effectively reduce radiation exposure to surgeons by about 40%.
Related Concept Videos
Biological Effects of Radiation
Radiation: Applications
The average...
Concentration Cells
Consider the following voltaic cell:
Absorption of Radiation
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Generating Electromagnetic Radiations