Related Experiment Video
Updated: Feb 6, 2026

Generating Lap Joints Via Friction Stir Spot Welding on DP780 Steel
Published on: August 13, 2019
Experimental and Numerical Assessment of Temperature Field and Analysis of Microstructure and Mechanical Properties
Uday Kumar1, D K Gope2, J P Srivastava3
1Department of Mechanical Engineering, Indian Institute of Technology (ISM) Dhanbad, Dhanbad 826004, India. kumaruday2404@gmail.com.
Abstract:
In this present work, laser welding experiments were carried out on 1 mm thin Ti6Al4V sheets using a low power Nd-YAG laser machine without using any filler wire and without edge preparation of welding specimens. The influence of different major process control parameters such as welding speed and power on the yield parameters like temperature field, weld bead geometry, microstructure, and mechanical properties are critically investigated. Experimental results are compared in detail with the simulated results obtained using a commercial 3D finite element model. In the simulation model, temperature-dependent thermal and mechanical properties of plates were considered. The temperature readings were recorded with the aid of K type thermocouples. Forced convection has been assumed near weld zone region because of the movement of the shielding gas. Appreciable agreement is found between the experimental and the simulated temperature fields in most of the cases with few exceptions. These deviations on few occasions may be due to the presence of uncertainties inherently present in the experimental domain and uncertainties in the subsequent temperature sensing techniques by the thermocouples. In addition, annealing has been done at 950 °C, 980 °C, and 1010 °C for one selected parameter (192 W, 6 mm/s). The tensile strength of the samples annealed at 980 °C has been found to be 1048 MPa and it is 3% to 4% higher than that of the usual welded samples.
More Related Videos
Related Concept Videos
Properties of Electric Field Lines
For one, the electric field of a positive charge must originate from it. That is because its electric field points away from it. Moreover, since the magnitude of the field asymptotes to zero at infinity, the...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Numerical Calculations
The solution to a problem is obtained using different methods. While manually solving algebraic symbols is one of the most common methods, the graphical method is often preferred. Computers...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...

