Related Experiment Video
Updated: Feb 6, 2026

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Optical properties and surface roughness of prepolymerized poly(methyl methacrylate) denture base materials
Gülce Alp1, William M Johnston2, Burak Yilmaz3
1Former Visiting Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio; Assistant Professor, Department of Prosthodontics, Okan University Faculty of Dentistry, Istanbul, Turkey.
New computer-assisted design and computer-assisted manufacturing (CAD-CAM) poly(methyl methacrylate) (PMMA) denture materials show good color stability after coffee thermocycling. Surface roughness remained below the plaque accumulation threshold, indicating suitability for dental prosthetics.
Area of Science:
- Dental Materials Science
- Biomaterials Engineering
- Prosthodontics
Background:
- Limited data exists on the color stability, translucency, and surface roughness of novel computer-assisted design/computer-assisted manufacturing (CAD-CAM) prepolymerized poly(methyl methacrylate) (PMMA) denture base materials.
- Understanding these properties is crucial for evaluating the clinical performance and longevity of CAD-CAM PMMA restorations.
Purpose of the Study:
- To assess the color stability, relative translucency, and surface roughness of conventional and various prepolymerized CAD-CAM PMMA denture base materials.
- To investigate the effects of simulated coffee thermocycling (CTC) on these properties.
Main Methods:
- Six disk-shaped specimens of three CAD-CAM PMMA brands and one conventional PMMA were prepared and polished.
- Specimens underwent 5000 cycles of coffee thermocycling.
- Surface roughness (Ra) and color stability (CIEDE2000) were measured before and after CTC using a contact profilometer and spectroradiometer, respectively. Relative translucency parameter (RTP) was also calculated.
Main Results:
- Coffee thermocycling (CTC) did not significantly alter the color of any tested PMMA materials.
- A significant interaction between material type and CTC was observed for relative translucency (P=.011).
- CTC increased surface roughness (P=.031) for all materials, but values remained below the 0.2 μm plaque accumulation threshold.
Conclusions:
- All tested PMMA denture base materials exhibited clinically imperceptible color changes after 5000 CTC.
- One CAD-CAM material demonstrated significantly lower relative translucency compared to others, both before and after CTC.
- The surface roughness of all evaluated denture base materials remained below the threshold for plaque accumulation.
Related Concept Videos
Properties of Enantiomers and Optical Activity
Directing Proteins to the Rough Endoplasmic Reticulum
Members Made of Elastoplastic Material
As the bending moment...
Genetic Material
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Physical and Chemical Properties of Matter