Optimized in vivo brain glutamate measurement using long-echo-time semi-LASER at 7 T
Dickson Wong1,2, Amy L Schranz1,2, Robert Bartha1,2
1Department of Medical Biophysics, The University of Western Ontario, London, ON, Canada.
Abstract:
A short echo time (TE ) is commonly used for brain glutamate measurement by 1 H MRS to minimize drawbacks of long TE such as signal modulation due to J evolution and T2 relaxation. However, J coupling causes the spectral patterns of glutamate to change with TE , and the shortest achievable TE may not produce the optimal glutamate measurement. The purpose of this study was to determine the optimal TE for glutamate measurement at 7 T using semi-LASER (localization by adiabatic selective refocusing). Time-domain simulations were performed to model the TE dependence of glutamate signal energy, a measure of glutamate signal strength, and were verified against measurements made in the human sensorimotor cortex (five subjects, 2 × 2 × 2 cm3 voxel, 16 averages) on a 7 T MRI scanner. Simulations showed a local maximum of glutamate signal energy at TE = 107 ms. In vivo, TE = 105 ms produced a low Cramér-Rao lower bound of 6.5 ± 2.0% across subjects, indicating high-quality fits of the prior knowledge model to in vivo data. TE = 105 ms also produced the greatest glutamate signal energy with the smallest inter-subject glutamate-to-creatine ratio (Glu/Cr) coefficient of variation (CV), 4.6%. Using these CVs, we performed sample size calculations to estimate the number of participants per group required to detect a 10% change in Glu/Cr between two groups with 95% confidence. 13 were required at TE = 45 ms, the shortest achievable echo time on our 7 T MRI scanner, while only 5 were required at TE = 105 ms, indicating greater statistical power. These results indicate that TE = 105 ms is optimum for in vivo glutamate measurement at 7 T with semi-LASER. Using long TE decreases power deposition by allowing lower maximum RF pulse amplitudes in conjunction with longer RF pulses. Importantly, long TE minimizes macromolecule contributions, eliminating the requirement for acquisition of separate macromolecule spectra or macromolecule fitting techniques, which add additional scan time or bias the estimated glutamate fit.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Antiepileptic Drugs: Glutamate Antagonists
Optimal Foraging
Optimization Problems
Optimal Arousal Theory
Inverted U-Shaped Performance Curve
The...
Measurement: Standard Units