Related Experiment Video
Updated: Feb 6, 2026

Brain State-dependent Brain Stimulation with Real-time Electroencephalography-Triggered Transcranial Magnetic Stimulation
Published on: August 20, 2019
Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain
Andrada Ianuş1, Sune N Jespersen2, Teresa Serradas Duarte3
1Champalimaud Neuroscience Programme, Champalimaud Centre for the Unknown, Lisbon, Portugal; Centre for Medical Image Computing, University College London, London, UK.
Abstract:
Microscopic diffusion anisotropy (μA) has been recently gaining increasing attention for its ability to decouple the average compartment anisotropy from orientation dispersion. Advanced diffusion MRI sequences, such as double diffusion encoding (DDE) and double oscillating diffusion encoding (DODE) have been used for mapping μA, usually using measurements from a single b shell. However, the accuracy of μA estimation vis-à-vis different b-values was not assessed. Moreover, the time-dependence of this metric, which could offer additional insights into tissue microstructure, has not been studied so far. Here, we investigate both these concepts using theory, simulation, and experiments performed at 16.4T in the mouse brain, ex-vivo. In the first part, simulations and experimental results show that the conventional estimation of microscopic anisotropy from the difference of D(O)DE sequences with parallel and orthogonal gradient directions yields values that highly depend on the choice of b-value. To mitigate this undesirable bias, we propose a multi-shell approach that harnesses a polynomial fit of the signal difference up to third order terms in b-value. In simulations, this approach yields more accurate μA metrics, which are similar to the ground-truth values. The second part of this work uses the proposed multi-shell method to estimate the time/frequency dependence of μA. The data shows either an increase or no change in μA with frequency depending on the region of interest, both in white and gray matter. When comparing the experimental results with simulations, it emerges that simple geometric models such as infinite cylinders with either negligible or finite radii cannot replicate the measured trend, and more complex models, which, for example, incorporate structure along the fibre direction are required. Thus, measuring the time dependence of microscopic anisotropy can provide valuable information for characterizing tissue microstructure.
More Related Videos
Related Concept Videos
Chronopharmacokinetics: Time-Dependent Pharmacokinetics
Time-dependent pharmacokinetics refers to non-cyclical changes in drug rate processes over a period of time. It can lead to nonlinear pharmacokinetics, where the relationship between drug concentration and time is not proportional. Non-cyclical...
Diffusion
Diffusion
The Integrated Rate Law: The Dependence of Concentration on Time
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion

