Related Experiment Video
Updated: Feb 6, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Automated Robust Proton Planning Using Dose-Volume Histogram-Based Mimicking of the Photon Reference Dose and
Roel G J Kierkels1, Albin Fredriksson2, Stefan Both1
1University of Groningen, University Medical Center Groningen, Department of Radiation Oncology, Groningen, the Netherlands.
Purpose:
Patient selection for proton therapy is increasingly based on proton to photon plan comparisons. To improve efficient decision making, we developed a dose mimicking and reducing (DMR) algorithm to automatically generate a robust proton plan from a reference photon dose, as well as target and organ at risk (OAR) delineations.
Methods And Materials:
The DMR algorithm was evaluated in 40 patients with head and neck cancer. The first step of the DMR algorithm comprises dose-volume histogram-based mimicking of the photon dose distribution in the clinical target volumes and OARs. Target robustness is included by mimicking the nominal photon dose in 21 perturbed scenarios. The second step of the optimization aims to reduce the OAR doses while retaining the robust target coverage as achieved in the first step. We evaluated each DMR plan against the manually robustly optimized reference proton plan in terms of plan robustness (voxel-wise minimum dose). Furthermore, the DMR plans were evaluated against the reference photon plan using normal tissue complication probability (NTCP) models of xerostomia, dysphagia, and tube feeding dependence. Consequently, ΔNTCPs were defined as the difference between the NTCPs of the photon and proton plans.
Results:
The dose distributions of the DMR and reference proton plans were very similar in terms of target robustness and OAR dose values. Regardless of proton planning technique (ie, DMR or reference proton plan), the same treatment modality was selected in 80% (32 of 40) of cases based on the ∑ΔNTCPs. In 15% (6 of 40) of cases, a conflicting decision was made based on relatively small dose differences to the OARs (<2.0 Gy).
Conclusions:
The DMR algorithm automatically optimized robust proton plans from a photon reference dose that were comparable to the dosimetrist-optimized proton plans in patients with head and neck cancer. This algorithm has been successfully embedded into a framework to automatically select patients for proton therapy based on NTCPs.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Dose-Response Relationship: Overview
Drug Dosing: Infants and Children